Cột sắc ký Agilent DB-5 Series, J&W GC ColumnsCột sắc ký Agilent DB-5 Series, J&W GC Columns
Agilent J&G Clolumns lidinco 1Agilent J&G Clolumns lidinco 1
Cột sắc ký Agilent DB-5 Series, J&W GC ColumnsCột sắc ký Agilent DB-5 Series, J&W GC Columns

Cột sắc ký Agilent DB-5 Series, J&W GC Columns

• Hãng sản xuất

Model

Bảo hành

 Agilent

DB-5 Series

12 tháng

Để có giá tốt nhất và nhanh nhất, vui lòng liên hệ

(08) 3977 8269 – (08) 3601 6797

Email: sales@lidinco.com – lidinco@gmail.com

  • Mô tả
  • Thông tin bổ sung
  • Thông số kỹ thuật

Mô tả

Cột sắc ký Agilent Db – 5 chuyên dụng trong phòng thí nghiệm nghiên cứu

Agilent J&W DB-5 is non-polar and low bleed, available in a range of column dimensions. DB-5 is also bonded, cross-linked and solvent-rinsable and has a high temperature limit. It is equivalent to USP phase G27. The DB-5 column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency.

Features

  • (5%-Phenyl)-methylpolysiloxane
  • Non-polar, low bleed and with a high temperature limit
  • Bonded, cross-linked and solvent rinsable
  • Wide range of column dimensions available
  • Wide range of applications
  • Excellent general purpose column
  • Equivalent to USP Phase G27
  • Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you with the utmost confidence in qualitative and quantitative results
  • For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column

Similar Phases: SPB-5, Rtx-5, BP-5, OV-5, 007-2(MPS-5), SE-52, SE-54, XTI-5, PTE-5, ZB-5, AT-5, MDN-5, ZB-5

Agilent J&G Clolumns lidinco 1 Agilent J&G Clolumns lidinco

Thông tin bổ sung

Hãng SX

Agilent

Specifications

Test Mix:

  • Microbore (0.05-0.10 mm id) Part No: 200-0010
  • Capillary (0.18-0.32 mm id) Part No: 200-0310
  • Megabore (0.45-0.53 mm id) Part No: 200-0110

Certain thick film or thin film configurations require different test mixtures than those listed above. 

Configuration choices for Agilent J&W DB-5

Microbore
ID (mm) 0.10 mm
Length (m) 10 – 20 m
Film (µm) 0.10 – 0.40 µm
Temperature Limits (°C) -60 – 325/350 °C
Capillary
ID (mm) 0.15 – 0.32 mm
Length (m) 10 – 60 m
Film (µm) 0.10 – 1.50 µm
Temperature Limits (°C) -60 – 300/320 °C (1.20 µm)
-60 – 325/350 °C
Megabore
ID (mm) 0.45 – 0.53 mm
Length (m) 10 – 60 m
Film (µm) 0.25 – 5.00 µm
Temperature Limits (°C) -60 – 260/280 °C (2.65, 3.00, 5.00 µm)
-60 – 300/320 °C