Series TH283X Compact LCR Meter 0.05%

Series TH283X Compact LCR Meter 0.05%

Model:
TH283X Series
Origin:
China
Manufacturer:
Price: Contact
  • Product Type:
  • Test Frequency:
  • Accuracy:
  • Available: Please contact
  • There are currently no promotions for this product

Hotline: +84 906 988 447    

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: [email protected]
  • Add: 487 Cong Hoa Street, Tan Binh Ward, Ho Chi Minh City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: [email protected]
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

TH2830

Basic Measurement Accuracy (See Details in Technical Specification):
LCRZ: 0.05%
DCR: 0.1%
Calibration Condition: Warm up time: ≥ 30 minutes; Environment temperature: 23±5ºC Signal level: 1Vrms;  Corretion: after OPEN, SHORT Testing cable length: 0 m

Test Signal Frequency: 50Hz-100kHz, 34points 50Hz, 60Hz, 75Hz, 100Hz, 120Hz, 150Hz, 200Hz, 250Hz, 300Hz, 400Hz, 500Hz, 600Hz, 750Hz, 1kHz, 1.2kHz, 1.5kHz, 2kHz,2.5kHz, 3kHz, 4kHz, 5kHz, 6kHz, 7.5kHz, 10kHz, 12kHz, 15kHz, 20kHz, 25kHz, 30kHz, 40kHz, 50kHz, 60kHz, 75kHz, 100kHz

Signal Source Output Impedance: Selectable 30Ω, 100Ω,  ±1% @1kHz

AC Test Signal Level:
Normal 10mV—2Vrms
Resolution: 10mV,Accuracy: 10% x setting voltage+2mV
100μA—20mArms
Resolution: 0.1mA

DCR test signal level: 1V DC

Test Parameters: |Z|,Y|, C, L, X, B, R, G, D, Q, θ, DCR

DCR display range: 0.00001 Ω – 99.9999 MΩ

LCR Parameters Display Range: |Z|, R, X0.00001Ω — 99.9999MΩ|Y|, G, B0.00001μs — 99.9999sC0.00001pF —  9.99999FL0.00001μH —  99.9999kHD0.00001 —  9.99999Q0.00001 — 99999.9θ(DEG)-179.999º — 179.999ºθ(RAD)-3.14159 — 3.14159Δ%-999.999% — 999.999%

Display Digits: 6

Measurement Time (≥10 kHz): Fast: 75 meas/sec(13ms), Medium:11 meas/sec(90 ms), Slow: 2.7meas/sec(370 ms)

Trigger Mode: Internal, Manual, External, Bus

Average Time: 1–255

TH2831

Basic Measurement Accuracy (See Details in Technical Specification):
LCRZ: 0.1%
DCR: 0.1%
Calibration Condition: Warm up time: ≥ 30 minutes; Environment temperature: 23±5ºC Signal level: 1Vrms;  Corretion: after OPEN, SHORT Testing cable length: 0 m

Test Signal Frequency: 50Hz-100kHz, 34points 50Hz, 60Hz, 75Hz, 100Hz, 120Hz, 150Hz, 200Hz, 250Hz, 300Hz, 400Hz, 500Hz, 600Hz, 750Hz, 1kHz, 1.2kHz, 1.5kHz, 2kHz,2.5kHz, 3kHz, 4kHz, 5kHz, 6kHz, 7.5kHz, 10kHz, 12kHz, 15kHz, 20kHz, 25kHz, 30kHz, 40kHz, 50kHz, 60kHz, 75kHz, 100kHz

Signal Source Output Impedance: Selectable 30Ω, 100Ω,  ±1% @1kHz

AC Test Signal Level:
Normal 10mV—2Vrms
Resolution: 10mV,Accuracy: 10% x setting voltage+2mV
100μA—20mArms
Resolution: 0.1mA

DCR test signal level: 1V DC

Test Parameters: |Z|,Y|, C, L, X, B, R, G, D, Q, θ, DCR

DCR display range: 0.00001 Ω – 99.9999 MΩ

LCR Parameters Display Range: |Z|, R, X0.00001Ω — 99.9999MΩ|Y|, G, B0.00001μs — 99.9999sC0.00001pF —  9.99999FL0.00001μH —  99.9999kHD0.00001 —  9.99999Q0.00001 — 99999.9θ(DEG)-179.999º — 179.999ºθ(RAD)-3.14159 — 3.14159Δ%-999.999% — 999.999%

Display Digits: 6

Measurement Time (≥10 kHz): Fast: 75 meas/sec(13ms), Medium:11 meas/sec(90 ms), Slow: 2.7meas/sec(370 ms)

Trigger Mode: Internal, Manual, External, Bus

Average Time: 1–255

TH2832

Basic Measurement Accuracy (See Details in Technical Specification):
LCRZ: 0.05%

Test Signal Frequency: 50Hz-100kHz, 34points 50Hz, 60Hz, 75Hz, 100Hz, 120Hz, 150Hz, 200Hz, 250Hz, 300Hz, 400Hz, 500Hz, 600Hz, 750Hz, 1kHz, 1.2kHz, 1.5kHz, 2kHz,2.5kHz, 3kHz, 4kHz, 5kHz, 6kHz, 7.5kHz, 10kHz, 12kHz, 15kHz, 20kHz, 25kHz, 30kHz, 40kHz, 50kHz, 60kHz, 75kHz, 100kHz

Signal Source Output Impedance: Selectable 30Ω, 100Ω,  ±1% @1kHz

AC Test Signal Level:
Normal 10mV—2Vrms
Resolution: 10mV,Accuracy: 10% x setting voltage+2mV
100μA—20mArms
Resolution: 0.1mA

DCR test signal level: 1V DC

Test Parameters: |Z|,Y|, C, L, X, B, R, G, D, Q, θ, DCR

DCR display range: 0.00001 Ω – 99.9999 MΩ

LCR Parameters Display Range: |Z|, R, X0.00001Ω — 99.9999MΩ|Y|, G, B0.00001μs — 99.9999sC0.00001pF —  9.99999FL0.00001μH —  99.9999kHD0.00001 —  9.99999Q0.00001 — 99999.9θ(DEG)-179.999º — 179.999ºθ(RAD)-3.14159 — 3.14159Δ%-999.999% — 999.999%

Display Digits: 6

Measurement Time (≥10 kHz): Fast: 75 meas/sec(13ms), Medium:11 meas/sec(90 ms), Slow: 2.7meas/sec(370 ms)

Trigger Mode: Internal, Manual, External, Bus

Average Time: 1–255

Brief Introduction

Adopting the latest technology & high density circuit design and concentrating the essence of LCR test, TH283X series is a new generation compact LCR meter of low cost and high performance.  Instead of traditional mechanical power switch, it adopts software control power switch.  The basic accuracy of 0.05% and good test stability can compare favourably with those high-end models. Being equipped with

4.3 inch TFT LCD Display and brand new interface system, TH283X series LCR meters possess elegant appearance and easy operation. Also, being provided with various interfaces and good compatibility with SCPI commands, TH283X series LCR meters are convenient for constituting all kinds of test system and satisfy various kinds of demands for inspection, production and scientific research.

Accessories

High Precision LCR Meter Matrix MCR-5010

Contact

High Frequency LCR Digital Bridge TongHui TH2836

Contact

High Frequency LCR Meter Matrix MCR-9030

Contact

Precision Capacitance Meter Tonghui TH2638C 1kHz

Contact

Precision Imdepance Analyzer Tonghui TH2851-030

Contact

Microtest Impedance Analyzer Microtest 6632-3

Contact

High Precision Professional Digital LCR Meter Twintex LCR-7200A

Contact

Precision LCR Meter Tonghui TH2827C

Contact