LCR-Reader-R2 Siborg
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: sales@lidinco.com
- Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: bn@lidinco.com
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
- Technical Counseling 100% Free
- Free Shipping For 3.000.000vnd Order
Data is being updated
Description
This new multimeter is based on the MPA model with the ability to test at 250 kHz frequency and includes a new feature, Analog Signature Analysis.
The new R2 uses a different and more powerful MCU than the MPA model, allowing to process measurements at higher frequencies. R2 also has increased stability over other models, due to the ability to switch the test signal source resistance from 100 Ohms to 1.4 kOhms. The higher source resistance reduces noise when measuring small resistances
Analog Signature Analysis is a circuit board troubleshooting technique that uses an AC sine wave across two points of an electronic component or circuit. The resulting waveform is displayed using voltage for the x axis and current as the y axis. The displayed signature is then comparable to a known good circuit board or component to determine the health of the tested board or component.
When the R2 was originally announced, it was said to have a 300 kHz test frequency; after some testing, this value was found to be too high without sacrificing test accuracy. Instead, in order to offer a 0.1% basic accuracy, the test frequency was lowered to 250 kHz. This test frequency, along with the change is source resistance, which is important while testing small capacitances and inductances and during in-circuit testing.
Major differences between LCR-Reader-R2 and LCR-Reader-MPA is the removal of Oscilloscope, AC/DC current and voltage measurements up to 15 V and the Frequency meter.
Feature
- Automatic and manual LCR, ESR, LED/Diode measurements
- 0.1% Basic accuracy
- Analog Signature Analysis
- Automatic test signal reduction to 0.1 V for in-circuit measurements
- Automatic and manual test frequencies, including 100, 120 Hz, 1, 10, 20, 30, 40, 50, 60, 75, 100 and 250 kHz
- Parasitic offset removal using easy Short/Open Calibration
- Measures components to a 0201 size (0.3 mm)
- 1.5 oz. weight
- Backlit LCD
- Displays active and reactive impedance components
- Gold-plated test leads
- NIST traceable calibration certificate
Accessories
Please login to write review!