TH2684 High Precision Insolution Resistance Tester

TH2684 High Precision Insolution Resistance Tester

SKU:
TH2684
Brand:
Warranty:
N/A
Price: Contact
  • Resistance Range:
  • Test Voltage:
  • Accuracy:
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Resistance Test  
Test Range:  kΩ to 50TΩ 
Test Accuracy: Test current > 100pA: 2%Test current ≤ 100 pA: 2% ± Vtest/2pA 

Current Test
Test Range
Range 1 :100uA – 1mA , Internal Input impedance 10 kΩ
Range 2 :10uA – 100uA , Internal Input impedance 10 kΩ
Range 3 :1uA – 10uA , Internal Input impedance 10 kΩ
Range 4 :100nA – 1uA , Internal Input impedance 10 kΩ
Range 5 :10nA – 100nA, Internal Input impedance 10 kΩ
Range 6 :1nA – 10nA, Internal Input impedance 10 kΩ or 1MΩ (selectable)
Range 7 :10pA – 1nA, Internal Input impedance 10 kΩ or 1MΩ (selectable)

Test Accuracy: 2% ± 2pA 

Voltage Test: 10 to 500V, 1V resolution

Accuracy: 2% of readout,or ± 1V 

Source Resistance: 200Ω 

Current Limit: 2,25,or 200mA

Voltage Output: Manually turn on or off on front panel, or controlled by built-in timer, or by remote control.

Timing: Programmable charge time: 0 to 1000s

Measurement Delay: 0 to 1000s programmable

Discharge Resistance: 2kΩ

Discharge Time: t = 0.03 x Cx (in μF), when Vtest falls to 1% of the test level.

Trig Mode: Single measurement: < 100ms(exclude charge time)Average up to 100 measurements:<100+ (N-1) x 100 ms (exclude charge)

Continuous Mode: Direct readout: 100ms – 10000ms depending on average number

Comparator: bins:(3 bins for PASS,1 bin for FAIL)

Range: Mode Auto, Hold

Average Times: to100

Memory: Sets of setup values can be stored.

Standard Interface: GPIB (optional), RS232C, HANDLER interface output, USBDEVICE ( USBTMC and USBCDC support), USBHOST, SCANNING

Description

Brief Introduction
■ TH2684/TH2684A High Precision IR Tester is an intelligent measurement instrument that is used for rapid measurements on IR properties of electronic parts and components, dielectric materials, equipments, cables, etc. Large LCD and user friendly menu provide you easier operation.

This instrument is especially designed for capacitor IR test TH2684/TH2684A can achieve rapid measurements through following methods:

  1. Selectable internal input impedance: If the current is greater than 10nA, only 10kΩ input impedance can be used; if the current is below 10nA, you can choose 10kΩ or 1MΩ impedance to test.
  2. With the built-in dual voltage output, TH2684 can charge large capacitors. By dual voltage output, TH2684 is able to output a precharge voltage up to 500V, 200mA. In voltage follow mode, precharge voltage follow with the test voltage output and can be finely adjusted. Above features ensure the perfect charge of capacitive materials.
  3. TH2684A can output a voltage of 1000V, 100mA to fully charge the capacitive material. In addition, user can program the sequence measurement steps (up to 18 steps) on TH2684/TH2684A. For instance, charge, wait, test, and discharge steps can be programmed. Each step can last up to 100s. 
    TH2684/TH2684A has a unique contact detection function. For capacitive material such as capacitors and cables, contact detection function can detect the contact of components under test. Moreover, this detection function will not increase any test time.

TH2684 equips with interfaces of RS232, USB DEVICE, SCANNING and Handler. Handler interface provide convenience for automatic test system; SCANNING interface is useful for mass measurement of components. User can use a scanner to speed measurement of components.

Performance characteristics

  • IR resistance test range: 10kΩ – 50TΩ
  • Charge current: 2mA, 25mA, 200mA
  • Test speed: 50ms
  • Accuracy: ±2% (<1TΩ)
  • Test voltage range: 10-500V, 1V step
  • 320×240 dot-matrix LCD
  • Ultra-low leakage current test: minimum current is 10pA, accuracy: 2% ±2pA
  • Dual outputs (precharge voltage output and test voltage output) can be set
  • The precharge voltage output can be set to follow the test voltage output and can be finely adjusted on test voltage. Also the precharge voltage can be set to work in independent mode
  • 100W powerful charging function
  • Contact detection function for capacitive components
  • When the test current is less than 10 nA, the internal input impedance can be selected between 10kΩ and 1MΩ to ensure rapid and accurate test
  • 7 current ranges, manual or auto range mode
  • 4-bin comparison function
  • Programmable sequence test mode
  • R-T and I-T Curve test and display mode
  • Screen hardcopy to be saved as BMP file to a U disk
  • Automatically upgrade firmware by a U disk
  • Achieve automatic test system by Handler interface
  • Achieve remote control by RS232C and USSB

Device interface

  • Support scanning interface for mass tests
  • Auto store setup parameters
  • Selectable Chinese and English operation interfaces

 

Specifications

el  TH2684  TH2684A  
Resistance Test  
Range  kΩ to 50TΩ  kΩ to 100TΩ  
Accuracy  Test current > 100pA: 2%Test current ≤ 100 pA: 2% ± Vtest/2pA  
Current Test  
Range  Range 1 :100uA – 1mA , Internal Input impedance 10 kΩ  
Range 2 :10uA – 100uA , Internal Input impedance 10 kΩ  
Range 3 :1uA – 10uA , Internal Input impedance 10 kΩ  
Range 4 :100nA – 1uA , Internal Input impedance 10 kΩ  
Range 5 :10nA – 100nA, Internal Input impedance 10 kΩ  
Range 6 :1nA – 10nA, Internal Input impedance 10 kΩ or 1MΩ (selectable)  
Range 7 :10pA – 1nA, Internal Input impedance 10 kΩ or 1MΩ (selectable)  
Accuracy  2% ± 2pA  
Measurement Voltage  
Range  10 to 500V, 1V resolution  to 1000V,1V resolution  
Accuracy  2% of readout,or ± 1V  
Source Resistance  200Ω  
Current Limit  2,25,or 200mA  2, 25 , or 100mA  
Voltage Output  Manually turn on or off on front panel, or controlled by built-in timer, or by remote control.  
Timing  Programmable charge time: 0 to 1000s  
Measurement Delay  0 to 1000s programmable  
Discharge Resistance  2kΩ  
Discharge Time  t = 0.03 x Cx (in μF), when Vtest falls to 1% of the test level.  
Measurement Speed  
Trig Mode  Single measurement: < 100ms(exclude charge time)Average up to 100 measurements:<100+ (N-1) x 100 ms (exclude charge)  
Continuous Mode  Direct readout: 100ms – 10000ms depending on average number  
Comparator  bins:(3 bins for PASS,1 bin for FAIL)  
Range Mode  Auto, Hold  
Average Times  to100  
Memory  Sets of setup values can be stored.  
Standard Interface  GPIB (optional), RS232C, HANDLER interface output, USBDEVICE ( USBTMC and USBCDC support), USBHOST, SCANNING  
Operating Temperature and Humidity  10°C – 40°C,  ≤90%RH  
Power Supply  to 130 V  AC(60Hz) orto 260V  AC(50HZ)  
Power Consumption  TH2684 : 250WTH2684A: 150W  
Dimensions (W×H×D)  430mm×400mm×130mm  