Power analyzer

Power analyzer

Mã:
N/A
Thương hiệu:
Bảo hành:
N/A
Giá: Liên hệ
  • Vui lòng liên hệ để kiểm tra tình trạng kho
  • Tạm thời chưa có khuyến mãi cho sản phẩm này

Hotline: 0906.988.447

Liên hệ: Hồ Chí Minh

  • Điện thoại: (028).3977.8269
  • Email: sales@lidinco.com
  • Địa chỉ: 487 Cộng Hòa, Phường 15, Quận Tân Bình, TP. HCM

Liên hệ: Bắc Ninh, Hà Nội

  • Điện thoại: (0222).730.0180
  • Email: bn@lidinco.com
  • Địa chỉ: 184 Bình Than, Phường Võ Cường, TP. Bắc Ninh
  • Tư vấn Tư vấn kĩ thuật Miễn phí
  • Giao hàng Miễn phí vận chuyển Đơn hàng trên 3 triệu
Thông số kỹ thuật

Dữ liệu đang được cập nhật

3

Power analyzers accurately measure electrical power characteristics of devices that generate, transform, or consume electricity. Power analyzers, also called power meters or wattmeters, provide precise measurements of true power (watts), power factor, harmonics and efficiency in inverters, motor drives, lighting, home appliances, office equipment, power supplies, and industrial machinery.

With advances in energy efficiency and standby power, there is an increasing demand for accurate and reliable power measurements. Highly stable and reliable power analyzers enable engineers to minimize energy loss due to distorted, transient waveforms in power electronics such as inverters, motors, lighting circuits, and power supplies. Yokogawa, the world's leading manufacturer of electrical power analyzers, provides a broad selection to satisfy all requirements.

Product Specifications
Volt Model Measurement Range Resolution Accuracy
Vrms (AC + DC) 1 V to 1000 V phase to neutral 0.01 V ±0.1% of nominal voltage1
Vpk 1 Vpk to 1400 Vpk 1 V 5% of nominal voltage
Voltage Crest Factor (CF) 1.0 > 2.8 0.01 ±5%
Vrms½   0.1 V ±0.2% of nominal voltage
Vfund   0.1 V ±0.1% of nominal voltage
Amps (accuracy excluding clamp accuracy)
Amps (AC + DC) i430-Flex 1x  5 A to 6000 A 1 A ±0.5% ±5 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ±0.5% ±5 counts
1mV/A 1x 5 A to 2000 A 1A ±0.5% ±5 counts
1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±0.5% ±5 counts
Apk i430-Flex 8400 Apk 1 Arms ±5%
1mV/A 5500 Apk 1 Arms ±5%
A Crest Factor (CF) 1 to 10 0.01 ±5%
Amps½ i430-Flex 1x 5 A to 6000 A 1 A ±1% ±10 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ±1% ±10 counts
1mV/A 1x 5 A to 2000 A 1 A ±1% ±10 counts
1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±1% ±10 counts
Afund i430-Flex 1x 5 A to 6000 A 1 A ±0.5% ±5 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ±0.5% ±5 counts
1mV/A 1x 5 A to 2000 A 1 A ±0.5% ±5 counts
1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±0.5% ±5 counts
Hz
Fluke 434 @ 50 Hz Nominal 42.50 Hz to 57.50 Hz 0.01 Hz ±0.01 Hz
Fluke 434 @ 60 Hz Nominal 51.00 Hz to 69.00 Hz 0.01 Hz ±0.01 Hz
Power
Watts (VA, var) i430-Flex max 6000 MW 0.1 W to 1 MW ±1% ±10 counts
1 mV/A max 2000 MW 0.1 W to 1 MW ±1% ±10 counts
Power Factor (Cos j/DPF) 0 to 1 0.001 ±0.1% @ nominal load conditions
Energy
kWh (kVAh, kvarh) i430-Flex 10x Depends on clamp scaling and V nominal ±1% ±10 counts
Energy Loss i430-Flex 10x Depends on clamp scaling and V nominal ±1% ±10 counts Excluding line resistance accuracy
Harmonics
Harmonic Order (n) DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
Inter-Harmonic Order (n) OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
Volts % f 0.0% to 100% 0.1% ±0.1% ±n x 0.1%
r 0.0% to 100% 0.1% ±0.1% ±n x 0.4%
Absolute 0.0 to 1000 V 0.1 V ±5%1
THD 0.0% to 100% 0.1% ±2.5%
Amps % f 0.0% to 100% 0.1% ±0.1% ±n x 0.1%
r 0.0% to 100% 0.1% ±0.1% ±n x 0.4%
Absolute 0.0 to 600 A 0.1 A ±5% ±5 counts
THD 0.0% to 100% 0.1% ±2.5%
Watts % f or r 0.0% to 100% 0.1% ±n x 2%
Absolute Depends on clamp scaling and V nominal ±5% ±n x 2% ±10 counts
THD 0.0% to 100% 0.1% ±5%
Phase Angle -360° to +0° ±n x 1°
Flicker
Plt, Pst, Pst (1 min) Pinst 0.00 to 20.00 0.01 ±5%
Unbalance
Volts % 0.0% to 20.0% 0.1% ±0.1%
Amps % 0.0% to 20.0% 0.1% ±1%
Mains Signaling
Threshold Levels Threshold, limits and signaling duration is programable for two signaling frequencies
Signaling Frequency 60 Hz to 3000 Hz 0.1 Hz  
Relative V % 0% to 100% 0.10% ±0.4%
Absolute V3s (3 second avg.) 0.0 V to 1000 V 0.1 V ±5% of nominal voltage
General Specifications
Case Design Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
Display Brightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
Memory 8GB SD card (SDHC compliant, FAT32 formatted) standard, upto 32 GB optionally Screen save and multiple data memories for storing data including recordings (dependent on memory size)
Real-Time Clock Time and date stamp for Trend mode, Transient display, System Monitor and event capture
Environmental
Operating Temperature 0°C ~ +40°C; +40°C ~ +50°C excl. battery
Storage Temperature -20°C ~ +60°C
Humidity +10°C ~ +30°C: 95% RH non-condensing +30°C ~ +40°C: 75% RH non-condensing +40°C ~ +50°C: 45% RH non-condensing
Maximum Operating Altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V Maximum storage altitude 12 km (40,000 ft)
Electro-Magnetic-Compatibility (EMC) EN 61326 (2005-12) for emission and immunity
Interfaces Mini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
  • B8506ZL Alligator Clipadapter Set
  • 257875 RJ Sensor
  • B8506ZK Measurement Lead Set
  • Safety Terminal Adapter Set B8213ZA
  • Measurement lead 758933
  • Connection Cable 705926
  • B8506WA Measurement Lead Set
  • BNC cable 366925
  • Safety Terminal Adapter Set 758931
  • CT1000/CT200/CT60 AC/DC Current Sensors
  • Current Sensor Unit 751522/751524
  • Measurement lead set 758917
  • 96001/751552 Current Clamp-On Probe
  • Conversion Adapter 366921
  • Conversion Adapter 758924
  • Small Alligator-clip Adapter 758922
  • Large Alligator-clip Adapter 758929
  • Fork terminal adapter 758921
  • Safety Terminal Adapter Set 758923
  • B9284LK External Sensor Cable
  • B9316FX

Phụ kiện

Máy hiện sóng Tektronix MSO46B 1.5GHz 6 kênh

Liên hệ

Máy hiện sóng Tektronix MSO44B 200MHz - 1.5GHz

Liên hệ

Máy hiện sóng Tektronix MDO32

Liên hệ

Máy phát xung Tektronix AWG70001B

Liên hệ

Máy phát xung Tektronix AWG70002B

Liên hệ

Máy phát xung Tektronix AWG5204

Liên hệ

Máy phát xung Tektronix AWG5208

Liên hệ

Máy phát xung Tektronix AWG5202

Liên hệ
Đánh giá & nhận xét

0.0/5

(0 đánh giá)
  • 5 0
  • 4 0
  • 3 0
  • 2 0
  • 1 0

Vui lòng đăng nhập để viết đánh giá!