Máy hiện sóng, Oscilloscope LeCroy HDO4024 200 MHz, 4 CH

Máy hiện sóng, Oscilloscope LeCroy HDO4024 200 MHz, 4 CH

• Hãng sản xuất

Model

Bảo hành

 LeCroy

HDO4024

12 tháng

 

Để có giá tốt nhất và nhanh nhất, vui lòng liên hệ

(08) 3977 8269 – (08) 3601 6797

Email: sales@lidinco.com – lidinco@gmail.com

  • Mô tả
  • Thông số kỹ thuật

Mô tả

Máy hiện sóng, Oscilloscope LeCroy HDO4024 200 MHz, 4 CH

Máy hiện sóng LeCroy HDO4022 băng thông 200 MHz, lấy mẫu 2.5 GSa/s, 4 kênh, bộ nhớ 12.5 Mpts/kênh, màn hình cảm ứng 12.1 inch.

Key Features
  • 12-bit ADC resolution, up to 15 bit with enhanced resolution
  • 200 MHz, 350 MHz, 500 MHz, 1 GHz bandwidths
  • Long Memory – up to 25 Mpts/Ch (50 Mpts interleaved)
  • 12.1” touch screen display
  • WaveScan – Advanced Search and Find
  • LabNotebook Documentation and Report Generation
  • History Mode – Waveform Playback
  • Spectrum Analyzer Mode
  • Power Analysis Software
  • Serial Data Trigger and Decode
  • 16 Digital Channels with 1.25 GS/s Sample Rate
  • Mixed Signal Debug Capabilities
    • Analog and Digital Cross Pattern Triggering
    • Digital Pattern Search and Find
    • Analog and Digital Timing Measurements
    • Activity Indicators
HD4096 High Definition Technology

HD4096 high definition technology enables oscilloscopes to capture and display signals of up to 1 GHz with high sample rate and 16 times more resolution than other oscilloscopes.

Benefits of HD4096 Technology

Waveforms captured and displayed on oscilloscopes with HD4096 technology are cleaner and crisper. Signal details often lost in the noise are clearly visible and easy to distinguish HD4096 enables oscilloscopes to deliver unmatched measurement precision for improved debug and analysis.

Mixed Signal – No Compromises

Debug complex embedded designs with integrated 16 channel mixed signal capability

Identify and Isolate Problems Fast

Quickly locate analog or digital waveforms for runts, glitches or other anomolies with WaveScan

History Mode Waveform Playback

Scroll back in time to isolate anomalies and quickly find the source of the problem.

Touch Screen Simplicity

Easily control channels, trigger, math and measurements with the large multi-touch display and intuitive interface.

Sequence Mode

Capture many fast pulses in quick succession or events separated by long periods of time.

Serial Bus Trigger and Decode

View decoded protocol information on top of physical layer waveforms and trigger on protocol specific messages

Save, Document, Report

Save all results and data with a single button press and create custom reports with LabNotebook

Simple Power Measurements

Measure and analyze operating characteristics of power conversion devices and circuits

Spectrum Analyzer Interface

View signal details in the frequency domain with a spectrum analyzer style user interface

Advanced Math and Measure

Use automatic measurement parameters and math functions to understand every waveform detail

Cross Triggering

Flexible analog and digital cross-pattern triggering across all 20 channels

Digital Timing Measurements

Perform timing measurements on digital signals and analyze with trends, statistics and histicons

Parallel Pattern Search

Find a digital pattern across many digital lines using the parallel pattern search capability of WaveScan

Activity Indicators

Quickly see the state of all the digital lines at the same time using convenient activity indicators.

 

Vertical System

Rise time 1.75 ns
Bandwidth 200 MHz
Input Channels 4
Bandwidth Limiters 20 MHz
Input Impedance 1 MΩ ±2.0% || 15 pF, 50 Ω ±2.0%
Input Coupling 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Maximum Input Voltage "50 Ω: 5 Vrms,
1 MΩ: 400 V max
(DC + Peak AC ≤ 10 kHz)"
Channel-Channel Isolation "DC-400MHz: 60 dB (>1000:1),
400MHz up to rated BW: 50 dB (>300:1),
(For any two ProBus input channels, same v/div settings, typical)"
Vertical Resolution 12 bits; up to 15 bits with enhanced resolution (ERES)
Sensitivity "50 Ω: 1 mV-1 V/div, fully variable;
1 MΩ: 1 mV-10 V/div, fully variable
50 ?: 1 mV/div - 1 V/div"
DC Gain Accuracy ±(0.5%) F.S, offset at 0 V
Offset Range 50Ω
+/-1.6V: 1mV/div-4.95mV/div
+/-4V: 5mV/div-9.9mV/div
+/-8V: 10mV/div-19.8mV/div
+/-10V: 20mV/div-1V/div1MΩ
+/-1.6V: 1mV/div-4.95mV/div
+/-4V: 5mV/div-9.9mV/div
+/-8V: 10mV/div-19.8mV/div
+/-16V: 20mV/div-100mV/div
+/-80V: 102mV/div-198mV/div
+/-160V: 200mV/div-1V/div
+/-400V: 1.02V/div-10V/div
 

Horizontal System

Time/Division Range 200 ps/div - 1.25 ks/div with standard memory (up to 2.5 ks/div with -L memory); RIS available at ≤10 ns/div; Roll Mode available at ≥100 ms/div and ≤5 MS/s
Clock Accuracy ±2.5ppm for 5 to 40C + 1.0ppm/year from calibration
Trigger and Interpolator Jitter 4.5 ps (rms)
 

Acquisition System

Single-Shot Sample Rate/Ch 2.5 GS/s
Equivalent Sample Rate 125 GS/s
Memory 25 Mpts/Ch on 2 Ch
12.5 Mpts/Ch on 4 Ch
 

Acquisition Modes

Averaging Up to 1,000,000
Peak Detect na
Interpolation Linear, Sin x/x
Enhanced Resolution Up to 15 bits
Sequence Mode Up to 10,000 segments
 

Triggering System

Modes Normal, Auto, Single, Stop
Sources Ch 1 - Ch 4, EXT, EXT/10, AC Line
Coupling Mode AC, DC, LF Rej, HF Rej
Pre-trigger Delay 0-100% of full scale
Post-trigger Delay 0-10,000 Divisions
Hold-off by Time or Events 2ns up to 20s
Internal Trigger Range ±4.1 Divisions
Trigger Sensitivity 0.9 division: 10 MHz
1.0 divisions: 100 MHz
2.0 divisions: 200 MHz
External Trigger Sensitivity 0.9 division: 10 MHz
1.0 divisions: 100 MHz
2.0 divisions: 200 MHz
External Trigger Input Range Ext: ±0.4 V, EXT/10: ±4.0 V
 

Display

Type Color Touch Screen 12.1" TFT-LCD
Resolution 1280 x 800
Grid Styles YT, XY
 

Trigger Types

Standard Triggers Edge, Glitch, Width, Logic (Pattern), TV (NTSC, PAL, SECAM, HDTV), Runt, Slew Rate, Interval, Dropout, Qualified
Optional Advanced Triggers na
Optional Serial Data Triggers I2C, SPI, UART/RS-232, CAN, LIN, FlexRay, SENT, MIL-STD-1553, ARINC 429, Audio (I2S, LJ, RJ, TDM), USB, USB-HSIC, MIPI D-PHY, DigRF3G
 

Internal Storage

Waveform Storage 4 memory waveforms plus internal HDD
Setup Storage 6 setups
 

Math

Number of Math Traces 2
Standard Math Functions Add, Subtract, Multiply, Divide, FFT, Absolute Value, Averaging (summed and continuous), Derivative, Envelope, Enhanced Resolution, Floor, Integral, Invert, Reciprocal, Rescale, Roof, Square, Square Root, Trend, Zoom
Optional Math Functions na
 

Measurements

Number of Measurements Displayed 8
Measurement Parameters Ampltidue, Area, Base, Delay, Delta Period @ Level, Delta Time @ Level, Duty Cycle, Duty @ Level, Edge @ Level, Fall Time (90% - 10%), Fall Time (80% - 20%), Frequency, Frequency @ Level, Maximum, Mean, Minimum, Overshoot+, Overshoot-, Period, Peak-Peak, Period, Period @ Level, Phase, Rise Time (10% - 90%), Rise Time (20% - 80%), RMS, Skew, Standard Deviation, Time @ Level, Top, Width+, Width-
 

Interface

GPIB Port 1 (optional)
USB (Device) 1
Ethernet Port 1
USB (Host) 6
Serial Port 0
 

Probes

Probes Qty. (4) ÷10 Passive Probes
Scale Factors Automatic/Manual: ÷1, ÷10, ÷20, ÷100, ÷200, ÷1000, ÷2000, ÷10000
Variable: (÷1x10-6 - ÷10000)
Calibration Output 1 kHz square wave, 1.0 Vp-p,
output to probe hook
 

Power Requirements

Voltage 90 - 264 VAC, 45 HZ - 66 Hz
90 - 132 VAC, 380 HZ - 420 Hz
Max. Power Consumption 330 VA
 

Environmental and Safety

Temperature (Operating) 5 °C to 40 °C
Temperature (Non-Operating) -20 °C to 60 °C
Humidity (Operating) 80% RH, 31 °C
50% RH, 40 °C
Humidity (Non-Operating) 95% RH
Altitude (Operating) 3,048 m max at <=30C
Altitude (Non-Operating) 12,192 m
 

Physical Dimensions

Dimensions (HWD) 291.7 mm x 399.4 mm x 131.31 mm
(11.48" x 15.72" x 5.17")