Benchtop Multimeter Keysight 3458A
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: [email protected]
- Add: 487 Cong Hoa Street, Tan Binh Ward, Ho Chi Minh City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: [email protected]
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh, Vietnam
-
Technical Counseling
100% Free
-
Free Shipping
For 3.000.000vnd Order
Data is being updated
Description
The Keysight 3458A has a 30-year industrial-benchmark legacy for remarkable DC accuracy and stability. The redesigned 3458A multimeter also has standard lab 8.5-digit precision with leading-edge DCV linearity accuracy, lowest internal noise, and it is RoHS compliant.
- Measure with confidence with up to 8 ppm 1-year direct current voltage (DCV) accuracy (4 ppm with option)
- Maximize productivity with fast measurement speeds up to 100,000 readings/s
- Prolonged data logging with up to 148,000 reading memory (now comes as standard)
- Self-adjusting and self-verifying auto-calibration capability
- Code compatible with previous version; RoHS compliant

Features:
With seven-function measurement flexibility and a convenient front panel, the 3458A enables:
- faster test system startup, faster test throughput, and longer system up-time
- usage as a calibration lab standard through its extraordinary linearity, low internal noise, and very high stability
- high-resolution digitizing with 16- to 24-bit resolution, up to 12 MHz bandwidth path, high sampling rate, and very low < 100 ps jitter performance
Specifications:
| Range | |
| DC volts | 0.1 V to 1000 V |
| AC volts | 10 mV to 1000 V |
| DC current | 100 nA to 1 A |
| AC current | 100 µA to 1 A |
| Ohms | 10 Ω to 1 GΩ |
| Frequency and period | 1 Hz to 10 MHz; : 100 ns to 1 sec |
| Maximum speeds | 100,000 readings/sec at 4.5 digits6 readings/sec at 8.5 digits |
| 3458A-001 | Extended Memory |
| 3458A-002 | High stability 4 ppm per year reference |
| 3458A-120 | 120-volt ac line selection |
| 3458A-220 | 220-volt ac line selection |
| 3458A-240 | 240-volt ac line selection |
| 3458A-907 | Front handle kit |
| 3458A-908 | Rack flange kit |
| 3458A-909 | Rack flange and front handle kit |
| 3458A-A6J | ANSI Z540-1-1994 Calibration |
| 3458A-ABA | English Printed Manual Set |
| 3458A-ABD | Germany - German manual |
| 3458A-ABF | France - French manual |
| 3458A-ABJ | Japan - Japanese manual |
| 3458A-ABZ | Italy - Italian localization |
| 3458A-H01 | Special 1000 vrms ac maximum input voltage |
| 3458A-H52 | US Air Force NSN |
| 3458A-OGC | Precision calibration, intended for metrology use only |
| 11059A | Kelvin Probe Set |
| 11062A | Kelvin Clip Set |
| 1CN006A | Handle Kit 88.1mm H (2U) - Two Front Handles |
| 34137A | Deluxe test lead set for the 3458A |
| 34191A | 2U Dual Flange Kit |
| 34308A | Thermistor Kit |
| 34330A | 30 A Current Shunt |
| E2308A | Thermistor Temperature Probe |
Accessories
| 3458A-001 | Extended Memory |
| 3458A-002 | High stability 4 ppm per year reference |
| 3458A-120 | 120-volt ac line selection |
| 3458A-220 | 220-volt ac line selection |
| 3458A-240 | 240-volt ac line selection |
| 3458A-907 | Front handle kit |
| 3458A-908 | Rack flange kit |
| 3458A-909 | Rack flange and front handle kit |
| 3458A-A6J | ANSI Z540-1-1994 Calibration |
| 3458A-ABA | English Printed Manual Set |
| 3458A-ABD | Germany - German manual |
| 3458A-ABF | France - French manual |
| 3458A-ABJ | Japan - Japanese manual |
| 3458A-ABZ | Italy - Italian localization |
| 3458A-H01 | Special 1000 vrms ac maximum input voltage |
| 3458A-H52 | US Air Force NSN |
| 3458A-OGC | Precision calibration, intended for metrology use only |
| 11059A | Kelvin Probe Set |
| 11062A | Kelvin Clip Set |
| 1CN006A | Handle Kit 88.1mm H (2U) - Two Front Handles |
| 34137A | Deluxe test lead set for the 3458A |
| 34191A | 2U Dual Flange Kit |
| 34308A | Thermistor Kit |
| 34330A | 30 A Current Shunt |
| E2308A | Thermistor Temperature Probe |
-
Current Range:
-
Voltage Range:
-
Display Resolution:
Digital Multimeters Siglent SDM4065A-SC
-
Current Range:
-
Voltage Range:
-
Display Resolution:
Digital Multimeters Siglent SDM4065A
-
Current Range:
-
Voltage Range:
-
Resistance Range:
-
Display Resolution:
Digital Multimeter Kikusui DME1600
-
Current Range:
-
Voltage Range:
-
Resistance Range:
-
Display Resolution:
Digital Multimeter Kikusui DME1600GC
-
Output Channel:
-
DC Supply Type:
-
Output Current:
-
Output Voltage:
Autoranging Power Supply Keysight E36231A 200W
-
Output Channel:
-
DC Supply Type:
-
Output Current:
-
Output Voltage:
Autoranging Power Supply Keysight E36232A 200W
-
Output Channel:
-
Output Current:
-
Output Voltage:
-
DC Supply Type:
Autoranging Dual Output Power Supply Keysight E36234A 400W
-
Output Channel:
-
Output Current:
-
Output Voltage:
-
DC Supply Type:
Autoranging Dual Output Power Supply Keysight E36233A 400W
-
Output Current:
-
Output Voltage:
-
Output Channel:
-
DC Supply Type:
Smart Bench Essentials DC Power Supply Keysight EDU36311A
-
Output Current:
-
Output Voltage:
-
Output Channel:
-
DC Supply Type:
DC Power Supply Keysight E36106B
-
Output Voltage:
-
Output Current:
-
Output Channel:
-
DC Supply Type:
DC Power Supply Keysight E36105B
Please login to write review!