AC/DC Power meter, Twintex TM-2212
-
Current Range:
-
Voltage Range:
-
Accuracy:
- Please contact to check stock
- There are currently no promotions for this product
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: sales@lidinco.com
- Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: bn@lidinco.com
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
- Technical Counseling 100% Free
- Free Shipping For 3.000.000vnd Order
Data is being updated
Description
TM-2212 is an AC/DC digital power meter with 16-bit CPU microprocessor,equipped with multifunction of full digitized measurement, calibration and output. The microprocessor has the advantage of high-speed sampling and calculation function to accurately measure the distortion signal of wave form. Except for its essential measurement on AC/DC voltage, AC/DC current, AC/DC watt, power factor, frequency and Crest Factor, the TM-2212 also provides additional features of PT/CT ratio setting, display value holding, range selecting, auto-ranging, etc.
Features:
- Measurements: V/A/W/VA/VAR/PF/Hz/CF
- Large screen LCD display, 4 or 6 parameters displayed simultaneously
- True RMS V, A, W
- Auto calibration via computer
- Data Hold / Range Hold function
- High immunity to external noise
- CT ratio(1~9999)
- RS-232 and RS485 interfaces
Specifications:
VOLTAGE | |
Range | 20.000Vpp, 50.00Vpp, 100.00Vpp, 200.00Vpp, 500.0Vpp, 1000.0Vpp 6 ranges by auto-range or manual |
Measurement type | True RMS |
Input impedance | ≥1MΩ |
Maximum input voltage | 1000V Peak |
PT ratio setting | 0.001 to 9999 |
Accuracy ( at 23℃ ± 5 ℃ ) | DC± 0.1% of reading ± 0.1% of range AC ± 0.1% of reading ± 0.1% of range (45 ~ 65Hz) AC ± 0.2% of reading ± 0.2% of range±0.1% of range (10~45Hz, 65~10kHz) |
CURRENT | |
Range | 1.0000App, 2.0000App, 5.000App, 10.000App, 20.000App 6 ranges by auto-range or manual |
Measurement type | True RMS |
Input impedance | ≥0.01Ω |
Maximum input voltage | 50A Peak (20A rms) |
CT ratio setting | 0.001 to 9999 |
Accuracy ( at 23℃ ± 5 ℃ ) | DC± 0.1% of reading ± 0.1% of range AC ± 0.1% of reading ± 0.1% of range (45~65Hz) AC ± 0.2% of reading ± 0.2% of range±0.1% of range (10~45Hz, 65~10kHz) |
WATT | |
Range | 0.001W~50kW |
Measurement type | True RMS |
Accuracy ( at 23℃ ± 5 ℃ ) | DC± 0.21% of reading ± 0.2% of range AC ± 0.2% of reading ± 0.2% of range (45~65Hz) AC ± 0.4% of reading ± 0.4% of range±0.2% of range (10~45Hz, 65~10kHz) |
POWER FACTOR | |
Range | 0.001 to 1.000 |
Computation | W/(VxA)=Power Factor (PF) |
FREQUENCY | |
Range | 0.0Hz to 599.9Hz 600Hz to5999 Hz 6.00kHz to 10.00 kHz |
Accuracy ( at 23℃ ± 5 ℃ ) | ± 0.2% of reading ±1 digit |
GENERAL | |
Display | Large screen LCD display, 4 or 6 parameters simultaneously |
Minimum input | 2 % of Range |
Response time | 3 cycles / sec |
Overload indicating | “PEAK” |
Temperature coefficient | ± 0.01% FS/℃ |
Operating environment | 0~50℃, RH<80 % |
Interface | RS232 and 485 |
Power source | AC90~260V, 50 / 60Hz |
Accessories | RS232 cable x1, RS485 cable x1, junction box x1, software CD x1, operation manual x1, power cord x1 |
Size & weight | 247W*89H*280D mm, approx.1.8kg |
Accessories
- RS232 cable x1
- RS485 cable x1
- junction box x1
- software CD x1
- operation manual x1
- power cord x1
Please login to write review!