UC2858X Power Transformer Comprehensive Test Instrument
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: sales@lidinco.com
- Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: bn@lidinco.com
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
- Technical Counseling 100% Free
- Free Shipping For 3.000.000vnd Order
Data is being updated
Brief introduction
– UC2858X is a multifunctional transformer testing system is used to test the various parts of the electronic transformer. The 5 inch LCD display is currently the most popular, users can be more intuitive, more comfortablereading test results. It is a transformer of a test system for high speed, high precision, high performance, can meet the quality control on production line, incoming inspection and lab measurement.
General features
– 5 inch LCD display
– U disk directly save the test results, more convenient
– 20Hz – 200kHz test frequency, resolution 10 mHz
The basic measurement – 0.05% accuracy, test speed (75 times / sec)
Automatic level control ALC function – Test of voltage or current.
– 30 ohm, 100 ohm, 10 /100, 10 /CC, four kinds of signal source outputimpedance
– built in the comparator, 10 file sorting and counting function.
In the 100 set of internal file or call U disk file or call 500 groups of test
– by USB HOST to realize the instrument software version upgrade and update
– U disk support FAT16 format, FAT32 file system
In standard RS232C, HANDLER, USB HOST, earphone interface, optional GPIB, LAN interface
Specifications
UC2858XB | 20 pin transformer scanning test | ||
Basic measurement accuracy | LCRZ | 0.05% | |
DCR, Laps than | 0.1% | ||
Calibration conditions | Preheat time: 30 minutes or more; Ambient temperature: 23 + / – 5 ° C; Signal voltage: 0.3 Vrms Vrms – 1 Clear the “0” : after the OPEN, SHORT; Testing cable length: 0 m | ||
Test signal frequency | UC2858XB | 50Hz – 200kHz | Minimum resolution 0.5 mHZ, Accuracy: 0.01% |
Signal source output impedance | 10Ω, 30Ω, 100Ω tùy chọn, ± 2% @ 1KHz | ||
AC test signal level | normal | 5mV-10Vrms 50μA-100mArms | |
A constant level | 10mV-5Vrms 100μA-50mArms | ||
Transformer test parameters | Circle number, circle number, phase, inductance and capacitance, leakage inductance and quality factor, the ac resistance, dc resistance, balance, pin short circuit; Turn Ratio, Turns, Phase, L, C, Lk, Q, ACR, DCR, Balance, Pin Short | ||
The LCR digital bridge test parameters | Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR, Turn-Ratio, pha, Lk | ||
DCR display range | 0.00001Ω – 999.999MΩ | ||
Laps than the display area | 1:0.001 – 1000:1 | ||
The LCR parameter range
| |Z|, R, X 0.00001Ω — 99.9999MΩ
|Y|, G, B 0.00001μs — 99.9999s C 0.00001pF — 9.99999F L 0.00001μH — 99.9999kH D 0.00001 — 9.99999 Q 0.00001 — 99999.9 θ(DEG) -179.999º — 179.999º θ(RAD) -3.14159 — 3.14159 Δ% -999.999% — 999.999% | ||
Measurement speed (10 kHz or higher) | Fast: 60 times per second (ms), medium speed: 11 times per second (90 ms) slow: 2.7 times per second (370 ms) | ||
The equivalent circuit | Series and parallel | ||
Range way | Automatically and keep | ||
Triggered | Internal, manual, the outside, the bus | ||
The average number | 1 – 255 | ||
The calibration function | Open circuit, short circuit, load |
Accessories
Please login to write review!