TH2684A High Precision Insolution Resistance Tester

TH2684A High Precision Insolution Resistance Tester

SKU:
TH2684A
Brand:
Warranty:
N/A
Price: Contact
  • Resistance Range:
  • Test Voltage:
  • Accuracy:
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Resistance Test  
Test Range: kΩ to 100TΩ
Test Accuracy: Test current > 100pA: 2%Test current ≤ 100 pA: 2% ± Vtest/2pA

Current Test
Test Range
Range 1 :100uA – 1mA , Internal Input impedance 10 kΩ
Range 2 :10uA – 100uA , Internal Input impedance 10 kΩ
Range 3 :1uA – 10uA , Internal Input impedance 10 kΩ
Range 4 :100nA – 1uA , Internal Input impedance 10 kΩ
Range 5 :10nA – 100nA, Internal Input impedance 10 kΩ
Range 6 :1nA – 10nA, Internal Input impedance 10 kΩ or 1MΩ (selectable)
Range 7 :10pA – 1nA, Internal Input impedance 10 kΩ or 1MΩ (selectable)

Test Accuracy: 2% ± 2pA

Voltage Test: 10 to 1000V,1V resolution

Accuracy: 2% of readout,or ± 1V

Source Resistance: 200Ω

Current Limit: 2, 25 , or 100mA

Voltage Output: Manually turn on or off on front panel, or controlled by built-in timer, or by remote control.

Timing: Programmable charge time: 0 to 1000s

Measurement Delay: 0 to 1000s programmable

Discharge Resistance: 2kΩ

Discharge Time: t = 0.03 x Cx (in μF), when Vtest falls to 1% of the test level.

Trig Mode: Single measurement: < 100ms(exclude charge time)Average up to 100 measurements:<100+ (N-1) x 100 ms (exclude charge)

Continuous Mode: Direct readout: 100ms – 10000ms depending on average number

Comparator: bins:(3 bins for PASS,1 bin for FAIL)

Range: Mode Auto, Hold

Average Times: to100

Memory: Sets of setup values can be stored.

Standard Interface: GPIB (optional), RS232C, HANDLER interface output, USBDEVICE ( USBTMC and USBCDC support), USBHOST, SCANNING

Description

Brief Introduction
■ TH2684/TH2684A High Precision IR Tester is an intelligent measurement instrument that is used for rapid measurements on IR properties of electronic parts and components, dielectric materials, equipments, cables, etc. Large LCD and user friendly menu provide you easier operation.

This instrument is especially designed for capacitor IR test TH2684/TH2684A can achieve rapid measurements through following methods:

  1. Selectable internal input impedance: If the current is greater than 10nA, only 10kΩ input impedance can be used; if the current is below 10nA, you can choose 10kΩ or 1MΩ impedance to test.
  2. With the built-in dual voltage output, TH2684 can charge large capacitors. By dual voltage output, TH2684 is able to output a precharge voltage up to 500V, 200mA. In voltage follow mode, precharge voltage follow with the test voltage output and can be finely adjusted. Above features ensure the perfect charge of capacitive materials.
  3. TH2684A can output a voltage of 1000V, 100mA to fully charge the capacitive material. In addition, user can program the sequence measurement steps (up to 18 steps) on TH2684/TH2684A. For instance, charge, wait, test, and discharge steps can be programmed. Each step can last up to 100s. 
    TH2684/TH2684A has a unique contact detection function. For capacitive material such as capacitors and cables, contact detection function can detect the contact of components under test. Moreover, this detection function will not increase any test time.

TH2684 equips with interfaces of RS232, USB DEVICE, SCANNING and Handler. Handler interface provide convenience for automatic test system; SCANNING interface is useful for mass measurement of components. User can use a scanner to speed measurement of components.

Performance characteristics

  • IR resistance test range: 10kΩ – 100TΩ
  • Charge current: 2mA, 25mA, 100mA
  • Test speed: 50ms
  • Accuracy: ±2% (<1TΩ)
  • Test voltage range: 10-1000V, 1V step
  • 320×240 dot-matrix LCD
  • Ultra-low leakage current test: minimum current is 10pA, accuracy: 2% ±2pA
  • Dual outputs (precharge voltage output and test voltage output) can be set
  • The precharge voltage output can be set to follow the test voltage output and can be finely adjusted on test voltage. Also the precharge voltage can be set to work in independent mode
  • 100W powerful charging function
  • Contact detection function for capacitive components
  • When the test current is less than 10 nA, the internal input impedance can be selected between 10kΩ and 1MΩ to ensure rapid and accurate test
  • 7 current ranges, manual or auto range mode
  • 4-bin comparison function
  • Programmable sequence test mode
  • R-T and I-T Curve test and display mode
  • Screen hardcopy to be saved as BMP file to a U disk
  • Automatically upgrade firmware by a U disk
  • Achieve automatic test system by Handler interface
  • Achieve remote control by RS232C and USSB

Device interface

  • Support scanning interface for mass tests
  • Auto store setup parameters
  • Selectable Chinese and English operation interfaces

Technical Parameter

Model   TH2684   TH2684A   
Resistance Test   
Range   kΩ to 50TΩ   kΩ to 100TΩ   
Accuracy   Test current > 100pA: 2%Test current ≤ 100 pA: 2% ± Vtest/2pA   
Current Test   
Range   Range 1 :100uA – 1mA , Internal Input impedance 10 kΩ   
Range 2 :10uA – 100uA , Internal Input impedance 10 kΩ   
Range 3 :1uA – 10uA , Internal Input impedance 10 kΩ   
Range 4 :100nA – 1uA , Internal Input impedance 10 kΩ   
Range 5 :10nA – 100nA, Internal Input impedance 10 kΩ   
Range 6 :1nA – 10nA, Internal Input impedance 10 kΩ or 1MΩ (selectable)   
Range 7 :10pA – 1nA, Internal Input impedance 10 kΩ or 1MΩ (selectable)   
Accuracy   2% ± 2pA   
Measurement Voltage   
Range   10 to 500V, 1V resolution   to 1000V,1V resolution   
Accuracy   2% of readout,or ± 1V   
Source Resistance   200Ω   
Current Limit   2,25,or 200mA   2, 25 , or 100mA   
Voltage Output   Manually turn on or off on front panel, or controlled by built-in timer, or by remote control.   
Timing   Programmable charge time: 0 to 1000s   
Measurement Delay   0 to 1000s programmable   
Discharge Resistance   2kΩ   
Discharge Time   t = 0.03 x Cx (in μF), when Vtest falls to 1% of the test level.   
Measurement Speed   
Trig Mode   Single measurement: < 100ms(exclude charge time)Average up to 100 measurements:<100+ (N-1) x 100 ms (exclude charge)   
Continuous Mode   Direct readout: 100ms – 10000ms depending on average number   
Comparator   bins:(3 bins for PASS,1 bin for FAIL)   
Range Mode   Auto, Hold   
Average Times   to100   
Memory   Sets of setup values can be stored.   
Standard Interface   GPIB (optional), RS232C, HANDLER interface output, USBDEVICE ( USBTMC and USBCDC support), USBHOST, SCANNING   
Operating Temperature and Humidity   10°C – 40°C,  ≤90%RH   
Power Supply   to 130 V  AC(60Hz) orto 260V  AC(50HZ)   
Power Consumption   TH2684 : 250WTH2684A: 150W   
Dimensions (W×H×D)   430mm×400mm×130mm   
Weight   TH2684 : 14kgTH2684A: 10kg   


 

 

Accessories