DC Ohm Meter Megaohm Tsuruga 3585

DC Ohm Meter Megaohm Tsuruga 3585

SKU:
3585
Brand:
Warranty:
N/A
Price: Contact
  • Resistance Range:
  • Test Voltage:
  • Accuracy:
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Data is being updated

Description

Typical Application

  • Coil, Power Supply Switch, Lead, Conductor

Model Designation

CODESPECIFICATION
XRS-232C output (standard)
03BCD output (TTL level) + RS-232C
04PBCD output (PNP) + RS-232C
04NBCD output (NPN) + RS-232C
07Analog voltage output + RS-232C

Basic Specifications

Measurement range

 
FOR ACCURACY IN MEDIUM SAMPLING, EXTRA 3 DGT IS ADDED.
MEASUREMENT RANGE30 mΩ300 mΩ 3 Ω30 Ω300 Ω3 kΩ30 kΩ300 kΩ
RESOLUTION1 μΩ10 μΩ100 μΩ1 mΩ10 mΩ100 mΩ1 Ω10 Ω
MEASURING CURRENTDC 300 mADC 100 mADC 10 mADC 1 mADC 10 μA
MAX. APPLIED VOLTAGE9 mV30 mV300 mV3 V300 mV3 V
ACCURACY± (0.2 % of rdg. + 10 dgt.)± (0.08 % of rdg. + 3 dgt.)
TEMPERATURE COEFFICIENT± (0.02 % of rdg. + 1 dgt.)/℃± (0.01 % of rdg. + 0.5 dgt.)/℃
OPEN TERMINAL VOLTAGEDC 6 V Max.
  • Accuracy: Specified at 23 ℃ ± 5 ℃, 45 to 75 %RH
    For accuracy in medium sampling, extra 3 dgt is added.
SAMPLING CYCLE: FAST MODE (MAX. DISPLAY 4 DGTS)
MEASUREMENT RANGE30 mΩ300 mΩ3 Ω30 Ω300 Ω3 kΩ30 kΩ300 kΩ
RESOLUTION10 μΩ100 μΩ1 mΩ10 mΩ100 mΩ1 Ω10 Ω100 Ω
MEASURING CURRENTDC 300 mADC 100 mADC 10 mADC 1 mADC 10 μA
MAX. APPLIED VOLTAGE9 mV30 mV300 mV3 V300 mV3 V
ACCURACY± (0.3 % of rdg. + 15 dgt.)± (0.2 % of rdg. + 5 dgt.)± (0.5 % of rdg. + 20 dgt.)
TEMPERATURE COEFFICIENT± (0.03 % of rdg. + 2 dgt.)/℃± (0.01 % of rdg. + 0.1 dgt.)/℃± (0.05 % of rdg. + 2 dgt.)/℃
OPEN TERMINAL VOLTAGEDC 6 V Max.
 
MEASUREMENT RANGE-19.9 to 199.9℃
RESOLUTION0.1℃
ACCURACY± (0.2 % of rdg. + 0.2℃)
TEMPERATURE COEFFICIENT± (0.02% of rdg. + 0.02 ℃)/℃
SENSORPt 100 Ω 3 lead wire type (Resistance of lead wire: Less than 5 Ω)
MEASURING CURRENT1 mA

Specification

MEASURING METHODDC 4 terminal method
MAX. ALLOWABLE APPLIED VOLTAGEAll range 100 V DC
DISPLAYOLED display
Max. display 35000
Zero suppress function
OVER DISPLAYOVER
SAMPLING CYCLE
SLOW:5 times/s
MEDIUM:20 times/s
FAST:90 times/s
RESPONSE SPEED
SLOW:Approx. 210 ms
MEDIUM:Approx. 57 ms
FAST:Approx. 20 ms

Time till judgment outputs, measured during HOLD while the specimen (fixed range) is connected.

ANALOG OUTPUTDC 3 V, output for display value 30000.
Load resistance: More than 2 kΩ
Conversion method: D/A conversion
Accuracy: ± 0.2 % of F.S.
INSULATION RESISTANCEPower supply terminal/Outer case  More than DC 500 V, 100 MΩ
Measruing terminal/Control terminal and RS-232C   More than DC 500 V, 10 MΩ
WITHSTAND VOLTAGEMeasuring terminals, control terminals, RS-232C/Outer case   AC 1500 V, 1 min
Power supply/Outer case AC 1500 V, 1 min
PARAMETER RETAINRetained in EEPROM during Power off
POWER SUPPLYAC 100 to 240 V (50/60 Hz)
POWER CONSUMPTION17 VA max.
OPERATING AMBIENT TEMPERATURE0 to 40 ℃
STORAGE TEMPERATURE-20 to 70 ℃
WEIGHTApprox. 1 kg
EXTERNAL DIMENSION205 (W) x 64 (H) x 169 (D) mm
ACCESSORIES
Power supply code1 pc
Control input connector1 pc
Utility software1 pc
Operation manual1 pc

Accessories