Specification

Data is being updated

WAVEJET354T

M áy hiện sóng  LeCroy WaveJet 354T băng thông 500 MHz, 4 kênh, lấy mẫu 1 GSa/s, bộ nhớ 2.5 Mpts/kênh, màn hình cảm ứng 7.5 inch.

Key Features
  • 350 MHz and 500 MHz bandwidths
  • Up to 2 GS/s sample rate
  • Long Memory – up to 5 Mpts
  • 7.5” touch screen display
  • 26 measurement parameters
  • Replay mode
  • Standard Pass/Fail Mask and Measurement testing
  • Standard I2C, SPI, and UART serial triggers
  • Standard USB Host, USB Device, GPIB, and LAN connectivity
  • Multi-language user-interface and help
  • Ultra-quick boot time
Touch Screen Control

Touch screen operation simplifies how all aspects of the oscilloscope are controlled, increasing productivity and decreasing setup time. Intuitively touch controls instead of navigating confusing soft keys.

Shorten Debug Time

Intricate signals can be quickly acquired by combining a long capture time with a variety of complex triggers, including triggers for I2C, SPI, and UART. Pass/fail mask and measurement testing enables deeper analysis and performs characterization and validation testing with ease. Scroll back in time to view previous waveforms and isolate anomalies using Replay mode.

Portable Performance

The small form factor and light-weight design make it easy to carry and use anywhere. Coupled with an ultra-quick boot time, the WaveJet Touch is ready to use when needed. The WaveJet Touch is on and acquiring signals in less than 5 seconds, enabling measurements to begin immediately.

Flexible Connectivity

Easily document results by saving screenshots directly to a memory stick or printer. Standard GPIB, LAN, and USB connections enable easy remote control. Using Teledyne LeCroy’s WaveStudio the WaveJet Touch can quickly connect to a PC.

Long Capture Time

Long memory is critical for maintaining high sample rate during long data captures. The standard 5 Mpts of memory eliminates the tradeoff between long capture and high sample rate. The long memory makes the WaveJet Touch a great tool for viewing signals that have low frequency and high frequency components. The built-in zoom function provides an easy way to get a close look at all of the signal details.

Advanced Triggering

Equipped with a variety of complex triggers, the WaveJet Touch can easily capture intricate signals. Standard I2C, SPI, and UART triggers allow for comprehensive protocol debug. A pattern logic trigger can trigger the oscilloscope depending upon the state of the four channel inputs.

Pass/Fail Testing

Waveforms can be tested against a mask or measurement parameters can be assigned pass/fail criteria for validation testing. On a pass/fail condition the oscilloscope can be configured to: stop the acquisition, beep, save the waveform, take a screen capture or output a pulse to another instrument.

Waveform Math and Analysis

Math operators include basic arithmetic functions and advanced FFT, derivative, and integral functions. Advanced math can be performed on the results of basic math functions. The scaling and offset of the math trace can easily be adjusted with its own dedicated knobs.

Digital FilteringDigital filtering is available on each channel. The Low-Pass, High-Pass, and Simple Moving Average filters allow the oscilloscope to isolate only the desired frequencies. By implementing the filter directly on each channel the math trace is still available for additional analysis.
Replay Mode Waveform Playback

Scroll back in time using Replay mode to view previous waveforms and isolate anomalies. Use cursors and measurement parameters to quickly find the source of problems. Replay mode is always active so there is no need to worry about turning it on.

Multiple Acquisition Modes

In addition to normal sampling, the high resolution, peak detect, and average acquisition modes make it easy to capture a wide range of signal types. An Equivalent time sampling rate of 100 GS/s allows for reconstruction of repetitive signal with extreme precision.

Automatic Measurements

Measure waveforms with up to 26 different automatic parameters and min/max statistics. Display up to four measurements simultaneously. All instance measurements allow the oscilloscope to measure all occurrences of a parameter in a single acquisition.

Vertical System

Rise time750 ps
Bandwidth500 MHz
Input Channels4
Bandwidth Limiters200 kHz, 2 MHz, 20 MHz, 100 MHz
Input Impedance1 MΩ ± 1.0% || 16 pF, 50 Ω ± 1.0%
Input CouplingAC, DC, GND
Maximum Input Voltage1 MΩ: ± 400 Vpk CAT I, 50 Ω: 5 VRMS
Channel-Channel Isolation≥ 40 dB from DC - 100 MHz ≥ 30 dB at 500 MHz
Vertical Resolution8 bits
Sensitivity1 MΩ: 2 mV/div - 10 V/div 50 Ω: 2 mV/div - 2 V/div
DC Gain Accuracy±(1.5% + 0.5% of Full Scale)
Offset Range±1 V: 2 mV/div - 50 mV/div ±10 V: 50.2 mV/div - 500 mV/div ±100 V: 502 mV/div - 10 V/div
 

Horizontal System

Time/Division Range500 ps/div - 50 s/div
Clock Accuracy10 ppm
Trigger and Interpolator Jitter150 ps (pk-pk)
 

Acquisition System

Single-Shot Sample Rate/Ch2 GS/s on 2 Ch 1 GS/s on 4 Ch
Equivalent Sample Rate100 GS/s
Memory5 Mpts/Ch on 2 Ch 2.5 Mpts/Ch on 4 Ch
 

Acquisition Modes

AveragingSelectable Number of Sweeps: 2 - 65536 (in powers of 2)
Peak Detect1 ns
InterpolationLinear
Enhanced ResolutionUp to 12 bits
 

Triggering System

ModesNormal, Auto, Single, Stop
SourcesCh 1 - Ch 4, EXT, EXT/10, AC Line
Coupling ModeAC, DC, LF Rej, HF Rej, Noise Reject
Hold-off by Time or Events200 ns - 50 s
Internal Trigger Range±5 divisions from center
Trigger Sensitivity0.5 division: DC - 10 MHz 1.0 division: 10 MHz - 250 MHz 1.5 divisions: 250 MHz - 500 MHz
External Trigger SensitivityExt: 50 mV from DC to 10 MHz 100 mV from 10 MHz to 250 MHz 150 mV from 250 MHz to 500 MHz Ext/10: 0.5 V from DC to 10 MHz 1.0 V from 10 MHz to 250 MHz 1.5 V from 250 MHz to 500 MHz
External Trigger Input RangeExt: ±0.5 V, EXT/10: ±5.0 V
 

Display

TypeColor Touch Screen 7.5" TFT-LCD
ResolutionVGA: 640 x 480
Grid StylesYT, XY
 

Trigger Types

Standard TriggersEdge, Edge ALT, Edge OR, Pulse Width, Period, Pulse Count, Dropout, TV, Logic, I2C, SPI, UART
 

Internal Storage

Waveform Storage1 reference waveform
Setup Storage5 setups
 

Math

Number of Math Traces1
Standard Math FunctionsAdd, Subtract, Multiply, FFT, Derivative, Integral
 

Measurements

Number of Measurements Displayed4
Measurement ParametersBase, Cyclical Mean, Cyclical RMS, Duty Cycle, Fall Time (90% - 10%), Fall Time (80% - 20%), Frequency, Integral, Maximum, Mean, Minimum, Number of +Pulses, Number of -Pulses, +Overshoot, -Overshoot, Peak-Peak, Period, +Pulse Width, -Pulse Width, Rise Time (20% - 80%), Rise Time (10% - 90%), RMS, Skew, Skew@level, Top, Top-Base
 

Interface

GPIB Port1
USB (Device)1
Ethernet Port1
USB (Host)1
 

Probes

ProbesQty. (4) ÷10 Passive Probes
Scale FactorsAutomatic: ÷1, ÷10, ÷100, ÷1000 Manual: ÷1, ÷5, ÷10, ÷20, ÷50, ÷100, ÷200, ÷500, ÷1000, ÷2000
Calibration Output1 kHz square wave, 3 Vp-p (typical), output to probe hook
 

Power Requirements

Voltage100 - 240 VAC (± 10%) at 50 / 60 Hz (± 5%) 100 - 120 VAC (± 10%) at 400 Hz (± 5%)
Max. Power Consumption50 W
 

Environmental and Safety

Temperature (Operating)0 °C to 40 °C
Temperature (Non-Operating)-20 °C to 60 °C
Humidity (Operating)80% RH, 40 °C
Humidity (Non-Operating)80% RH, 40 °C
Altitude (Operating)3,000 m max at <=25 °C
Altitude (Non-Operating)12,192 m
 

Physical Dimensions

Dimensions (HWD)190 mm x 330 mm x 124 mm (7.5" x 13" x 4.9")
Weight3.7 kg (8.6 lbs)

Accessories

Digital Multimeter Matrix MDM-8165A

Contact

Digital Multimeter Matrix MDM-8165

Contact

1-Door Large Sheet Steel Safety Cabinet ALT155

Contact

Safety cabinet Ecosafe 3030+1F

Contact

Data Acquisition system Placid PQ04S

Contact

DAQ Placid PQ401

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG500

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG350

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG200

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG120

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG80

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG60

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG30

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG40

Contact
Reviews & Comments

0.0/5

(0 ratings)
  • 5 0
  • 4 0
  • 3 0
  • 2 0
  • 1 0

Please login to write review!

Review about this product: