Description
BY ALL IMAGINATION, THE CADEX C8000 MAY WELL BE THE MOST COMPLETE BATTERY TESTING SYSTEM AVAILABLE.
The Cadex C8000 delivers the versatility needed to ensure you get the right performance from the batteries used in your applications. The C8000 is a multi-purpose tool that allows you to optimize batteries at every stage of product life.
You can capture load signatures of power tools and laptops and then perform simulated battery runtime by replying the stored data. Add a thermal chamber,
external load bank and other accessories, and you begin realizing that the
Cadex C8000 stands in a class by itself at an affordable price.
- Device Simulation helps you choose the right battery
- Life Cycle Testing helps you characterize the battery
- Custom Programming helps you monitor quality and performance
- Service Programs help you maintain the battery
DIGITAL ADVANTAGE
| Digital technology has the advantage of delivering extended test range, ultimate stability and high power in a compact housing. Each of the four channels can be programmed to 10A charge and discharge. Power handling is 100W per channel on charge and 80W on discharge, or 400W on charge and 320W on discharge on all four channels. The Cadex C8000 is more than a programmable power supply and load bank; the instrument provides intelligence to assist in battery testing. Protected charge and discharge algorithms with redundant safety features identify a faulty battery and safely terminate the service if so needed. The system can be overridden for destructive tests. |
I/O PORTS PROVIDE INDEPENDENT SERVICE
|
BUILDING A LABORATORY SYSTEM
|
MONITORING INDIVIDUAL CELLS
| Four differential (floating) analog inputs enable voltage check of up to 5 cells; 4 direct and one by voltage extraction. | ![]() |
LOAD CAPTURE
The Cadex C8000 captures load signatures and applies the simulated load as discharge protocol to check battery runtime. Learn how your battery will respond to your device.![]() |
LOAD CAPTURE UNIT (LCU)
| Captures load signatures of up to 100A and digitizes the information for reply in the C8000. The LCU is optional. | ![]() |
| For higher load currents than 10A per channel, you can connect the C8000 to a designated external load bank, enabling loads of up to 2,400 watts and 48 volts. Only one channel supports the external load bank. | ![]() |
DUAL POWER PORT CABLE (DPPC)
| The Dual Power Port Cable allows parallel connection of channels 1 and 2, or 3 and 4, to double the current handling from 10A to up to 20A. Only applies to discharge. | ![]() |
SMART BATTERY TESTING
| The Cadex C8000 reads the register settings of SMBus batteries. This verifies correct battery use and identifies anomalies. | ![]() |
LOAD TEST
| The Cadex C8000 allows testing batteries under GSM, CDMA or other discharge protocols. Programming is in 50μs intervals and the minimum setting is 500μs. The C8000 also offers dynamic stress tests to examine batteries under three different load conditions. | ![]() |
LIFECYCLE TEST
| This program assists in the selection of battery models and performs incoming inspection. The programs are fully automated, and PC-BatteryLab™ plots and stores the test results. | ![]() |
BATTERY INTERFACE MADE EASY
| The Adapter Unit provides a simple interface of over 1,500 Custom Battery Adapters, as well as the user-programmable Smart Cable and RigidArm™. | ![]() |
SERVICE PROGRAMS
Format, condition and restore batteries.
Charge — Applies fast charge; terminates charge when the battery is full; applies trickle charge (depending on battery chemistry)
Auto — Exercises batteries and applies recondition if the user-set target capacity cannot be reached (nickel-based batteries)
Prime — Prepares batteries by repeated cycling until maximum capacity is reached
Extended Prime — 16-hour trickle charge prior to Prime. Prepares difficult to charge batteries
Boost — Activates seemingly dead batteries.
RAPID TESTS
Checks battery without discharging.<>·····SYSTEM SPECIFICATIONS
| Standard Components | Each Standard System includes:- C8000 Test Unit- BatteryLab PC Software (CD-ROM) - 4 Power Port Cables - 4 Auxiliary Cables - 1 Dual Power Port Cable - 1 Ethernet Cable - 3AC Power Cords (N. America, Europe, UK type) - Rack Mounting Bracket Set for 19” 3U Rack - 1 QuickStart Guide |
| Channels | 4 Independent Channels each including:- 1 Battery Port + 1 I/O Port |
| Physical | |
| Dimensions | 480mm x 380mm x 140mm (18.9” x 15.0” x 5.5”) |
| Weight | 15.5 kg (34 lb) |
| Mounting Options | Desktop or 19” (483mm) 3U Rack-mount (brackets included) |
| Display | 5.7” (145mm) QVGA 320x240 graphics with backlight |
| Battery Ports (Front Panel) | 4 Ports each including:- Battery Positive (+)- Battery Negative (-) - Sense Positive (+) - Sense Negative (-) - Thermistor Input - Thermistor Ground |
| Input/Output (I/O) Ports (Front Panel) | 4 x DB25 Type each including:- 4 Differential Analog Inputs: 0-5V, 0-10V, or 0-15V- 4 Digital Inputs: 0-5V - SMBus Enabled: 5 Possible Termination Signals |
| Active Data Ports (Back Panel) | - Ethernet 10/100 MB for connection to PC - Designated Serial Port for External Load - Designated Serial Port for Environmental Chamber |
| Environment | |
| Recommended Operating Temperature | 5ºC-35ºC (40ºF-95ºF) |
| Recommended Storage Temperature | -20ºC-70ºC (-4ºF-160ºF) |
| Battery Testing | |
| Chemistries | All Standard Battery Types:- Lead Acid- Ni-based: NiMH, NiCd - Li-based: Li-ion, Li-Phosphate |
| Capacity Range | 50mAh to 1000Ah |
| Battery Interfaces | |
| Power Port Cable (Standard) - power | 4x 1.8m (6’) with alligator type clips |
| Auxiliary Cable (Standard) - data | 4x 1.8m (6’) |
| Dual Port Power Cable (Standard) - power | 1x 1.8m (6’) – connects to channels 1+2 or 3+4 to increase current capability from 10A to 20A |
| SnapLock Battery Adapter Unit (Optional) | 2-bay unit connects to C8000 standard cables supports:- SnapLock Battery Adapters (4-Wire type only)- RigidArm Universal Adapter |
| Electrical | |
| Input Power | - 100-240 VAC - 50-60 Hz |
| Battery Voltage Range | Nominal 1.2V-36V (max 45V) supports serial connection of:- Up to 10 Li-ion cells (3.6V/cell)- Up to 18 Lead Acid cells (2.0V/cell) - Up to 30 Nickel-based cells (1.2V/cell) – Note: 45V maximum total |
| Maximum Charge Power | 100W per channel = 400W total |
| Maximum Discharge Power | 80W per channel = 320W total 160W per channel pair using Dual Power Port cable External Load may be used to increase discharge up to 2400W |
| Maximum Charge/Discharge Current | 30mA to 10A set in 1mA increments 20A maximum discharge rate using Dual Power Port cable External Load may be used to increase discharge up to 240A |
| Output Frequency | - Square 2kHz (500 microseconds) |
| Accuracy | - Voltage = 0.1% - Current = 0.25% full scale |
| Power Management | Current automatically scaled down if power limits are exceeded – message indicates scaled test |
| Charge Methods | Charge methods are dependent upon chemistry:- Li-ion + Lead Acid = constant voltage with a current limit- Nickel-based = constant current with optional Reverse Load Charge method |
| Discharge Methods | - Constant current - Constant power |
| Data Acquisition | |
| System Sample Rate | 500 microseconds |
| Termination Data (last 500 samples) Capture Rate | 2-200 mS |
| Capture/Display Rate (non-termination) | 1-60 S |
| Load Capture | Minimum Sample Rate Increment = 500 microseconds # of Samples = 10-500 |
| Certification | |
| Safety | CSA, UL, CE |
| Environmental | RoHS, WEEE |
| Programs | |
| Service | Standard Service Programs:- Charge- Auto - Prime - Boost |
| Rapid Tests | Standard Rapid Tests:- OhmTest- Impedance |
| Advanced | Standard Advance Programs:- Runtime- Life Cycle - Self-Discharge - Discharge Only - CDMA - GSM - Extended Prime - Load Capture (requires BatteryLab + LCU) |
| SMBus | - Battery Info - Fuel Gauge Calibrate - SMB Charge - SMB Discharge |
| Custom (requires BatteryLab) | - Maximum Steps = 100 |
| External Test Equipment Control | |
| Environmental Chambers | Models supported:- Thermotron 2800/3800/8800- Test Equity Watlow 4 |
| External Digital Loads | B&K Precision Programmable DC Electronic Loads 8500 Series models supported:- 8510 (0.1V-120V/120A/600W)- 8514 (0.1V-120V/240A/1200W) - 8518 (0.1V-60V/240A/1200W) - 8520 (0.1V-120V/120A/2400W) |
| Load Capture | Cadex Load Capture Unit (LCU) |
| Security | Password protection |
| Warranty | |
| Standard | 2 year limited warranty (materials & workmanship) |
| Extended (Optional) | Additional 2 years (total = 4 years) |
| Calibration | Recommended factory calibration every 1 year Contact Cadex for further information |
| Upgrades | Firmware upgrades enabled by BatteryLab software |
| BatteryLab™: Technical Specifications | |
| System Requirements | PC with the following available:- Windows XP O/S- Ethernet connection - 1.2 GHz processor - 512 MB RAM - 10 GB storage memory |
| # of Test Systems | Each BatteryLab license operates:- Up to 8 C8000 test systems- Up to 32 individual batteries |