Automatic Transformer Test system Tonghui TH2840BX
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: sales@lidinco.com
- Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: bn@lidinco.com
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
- Technical Counseling 100% Free
- Free Shipping For 3.000.000vnd Order
Display :
Display 10.1" Captive Touch Screen
Ratio 16:09
Resolution 1280×RGB×800
Test PIN: 48PIN(Can extend to 288PIN)
Frequency:
Range: 20Hz-2MHz
Accuracy: 0.01%
Output impedance :
30Ω, ±4%@1kHz
100Ω, ±2%@1kHz
Test Parameter:
Method Arbitrary selection of four parameters
AC Cp/Cs, Lp/Ls, Rp/Rs, |Z|, |Y|, R, X, G, B, θ, D, Q, VAC, IAC
DC RDC, VDC, IDC
Cs, Cp: 0.00001pF-9.99999F
Ls, Lp: 0.00001μH-99.9999kH
D: 0.00001-9.99999
Q: 0.00001-99999.9
R, Rs, Rp, X, Z, RDC: 0.001mΩ-99.9999MΩ
G, B, Y: 0.00001μs-99.9999S
VDC: ±0V-±999.999V
IDC: ±0A-±999.999A
θr: -6.28318
θd: -179.999°-179.999°
Δ%: ±(0.000%-999.9%)
TurnsRatio: 1:0.001—1000:1
Output Voltage: 100-120VAC/198-242VAC Optional, 47-63Hz
Power Consumption: More than 130VA
Size (WxHxD) mm: 430mm(W)x177mm(H)x265mm(D)
Weight (kg): 11kg
Features
■ The test speed is as high as 1800 times/s (>10kHz), without relay action time
■ Test level up to 20Vrms
■ The bias voltage is built-in ±40V/±100mA/2A
■ Up to 288 test pins (only TH2840NX)
■ Industry-friendly user experience: Linux bottom layer, built-in help file
■ 10.1 inch 1280×800 capacitive touch screen
■ Graphical pin association setting page, so that wiring is no longer a problem
■ Lk setting does not need to input the leakage inductance pin, which is more intuitive
■ Enhanced balance scanning function, from 5 points to 10 points
■ Range switching adopts electronic switch, fast speed, long life, no noise
■ Optional LCR function
■ Approximately 100M setting file storage space in the machine, and massive U disk setting file storage capacity
■ Provide host computer to support early model file format conversion to ensure compatibility
Applications
■ Switching transformer scanning test, comprehensive characteristics analysis.
■ Network transformer scanning test, comprehensive characteristics analysis
■ Discrete passive components (L, R, C) multi-channel scanning test
■ Relay drive line package, contact resistance multi-channel scanning test
■ Multi-channel DC resistance DCR scanning test
■ Comprehensive test analysis of multiple passive components in impedance network
Accessories