Digital Storage Oscilloscope Siglent SDS3104X HD
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: sales@lidinco.com
- Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: bn@lidinco.com
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
-
Technical Counseling 100% Free
-
Free Shipping For 3.000.000vnd Order
Bandwidth: 1 GHz
Channels: 4 + EXT
Sample rate (Max.): 4 GSa/s
Memory depth (Max): 400 Mpts/ch
Waveform capture rate (Max.) : 890,000 wfm/s
Vertical resolution: 12-bit
Trigger type: Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Qualified, Nth edge, Setup/hold, Delay, Serial
Serial trigger and decode:
Standard: I2C, SPI, UART, CAN, LIN
Optional: CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester (decode only), ARINC429
Digital channel: 16-channel; maximum sample rate up to 1 GSa/s; record length up to 100 Mpts
Waveform generator: Single-channel SAG1021I, frequency up to 50 MHz, 125 MSa/s sample rate, 16 kpts waveform memory
I/O: USB 3.0 Host x2, USB 2.0 Host x1, USB 3.0 Device, 10M/100M/1000M LAN, External trigger, Auxiliary output (TRIG OUT, PASS/FAIL)
Display:10.1 TFT-LCD with capacitive touch screen (1024*600)
Dimensions (LxHxW): 317.2 mm × 236.0 mm × 149.0 mm
Net Weight: 4.1 kg
Product Overview
SIGLENT’s SDS3000X HD series Digital Storage Oscilloscopes are available in bandwidths of 1 GHz, 500 MHz and 350 MHz, have 12-bit ADCs with sample rate up to 4GSa/s, maximum record length of 400 Mpts/ch, and display up to 4 analog channels + 16 digital channels for high performance mixed signal analysis.
The SDS3000X HD series employs Siglent’s SPO technology with a maximum waveform capture rate of up to 200,000 wfm/ s, 256-level intensity grading display function plus a color temperature display mode. It also employs an innovative digital trigger system with high sensitivity and low jitter. The trigger system supports multiple powerful triggering modes including serial bus triggering. Tools such as History waveform recording, Search and Navigate functions, Mask Test, Bode Plot and Power Analysis allow for extended waveform records to be captured, stored, and analyzed. An impressive array of measurement and math capabilities, options for a 50 MHz arbitrary waveform generator, as well as serial decoding are also features of the SDS3000X HD .
The large 10.1’’ display capacitive touch screen supports multi-touch gestures, with the addition of user-friendly UI design, can greatly improve the operational efficiency. It also supports mouse control, and remote web control over LAN.
Key Features
- 4 analog channels, up to 1 GHz bandwidth with up to 4GSa/s sample rate
- 12-bit ADC
- Low background noise: 125 μVrms @ 1 GHz bandwidth
- SPO technology
- Waveform capture rates up to 200,000 wfm/s in Normal mode and 890,000 wfm/s in Sequence mode
- Supports 256-level intensity grading and color temperature display modes
- Up to 400 Mpts/ch record length
- Digital trigger system
- Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern, Qualified, Nth edge, Setup/hold, Delay and Video (HDTV supported). Zone Trigger simplifies advanced triggering
- Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester and ARINC429
- Segmented acquisition (Sequence) mode, dividing the maximum record length into multiple segments (up to 80,000), according to trigger conditions set by the user, with a very small dead time between segments to capture the qualifying event
- History waveform record (History) function, the maximum recorded waveform length is 80,000 frames
- Automatic measurements on 50+ parameters, supports statistics with histogram, track, trend, Gating measurement, and measurements on Math, History and Memory traces
- 4 Math traces (4 Mpts FFT, Filter, addition, subtraction, multiplication, division, integration, differential, square root, etc.), supports formula editor
- Abundant data analysis functions such as Search, Navigate, Digital Voltmeter, Counter, Waveform Histogram, Bode plot and Power Analysis
- High Speed hardware-based Average, ERES; High Speed hardware-based Mask Test function, with Mask Editor tool for creating user-defined masks
- 16 digital channels (optional)
- External 50 MHz waveform generator (optional)
- Large 10.1” TFT-LCD display with 1024 * 600 resolution; Capacitive touch screen supports multi-touch gestures
- Interfaces include: 2x USB 3.0 Host,1x USB 2.0 Host , USB 3.0 Device (USBTMC),1000M LAN ((VXI-11/Telnet/Socket/LXI)), External Triger In, Aux Out (Pass/Fail, Trigger Out)
- Built-in web server supports remote control over the LAN port using a web browser. Supports SCPI remote control commands. Supports external mouse and keyboard.
Accessories

-
Bandwidth:
-
Channels:
-
Sampling Rate:
-
Waveform Length:
Digital Storage Oscilloscope Siglent SDS7604A H12

-
Bandwidth:
-
Channels:
-
Sampling Rate:
Oscilloscope Tektronix MSO46B 200MHz - 1.5GHz

-
Bandwidth:
-
Channels:
-
Sampling Rate:
Mixed Signal Oscilloscope Tektronix MSO44B 200MHz - 1.5GHz

-
Bandwidth:
-
Sampling Rate:
-
Waveform Length:
-
Channels:
High Resolution Oscilloscope Micsig MHO68-350

-
Bandwidth:
-
Sampling Rate:
-
Waveform Length:
-
Channels:
High Resolution Oscilloscope Micsig MHO68-500

-
Bandwidth:
-
Sampling Rate:
-
Waveform Length:
-
Channels:
High Resolution Oscilloscope Micsig MHO68-1000

-
Bandwidth:
-
Sampling Rate:
-
Waveform Length:
-
Channels:
Automotive Oscilloscope Micsig VATO2004, 200MHz, 4 CH

-
Bandwidth:
-
Sampling Rate:
-
Waveform Length:
-
Channels:
Automotive Oscilloscope Micsig SATO2002, 200MHz, 2 CH

-
Output Channel:
-
Output Voltage:
-
Output Current:
Programmable DC Power Supply Siglent SPD3303X 3CH/32V/3A

-
Bandwidth:
-
Channels:
-
Sampling Rate:
-
Waveform Length:
Digital Storage Oscilloscope Siglent SDS7604A H12

-
Current Range:
-
Voltage Range:
-
Display Resolution:
Digital Multimeters Siglent SDM4065A-SC

-
Current Range:
-
Voltage Range:
-
Display Resolution:
Digital Multimeters Siglent SDM4065A

-
Output Current:
-
Output Voltage:
-
DC Supply Type:
-
Number Output:
Programmable Linear DC Power Supply Siglent SPD4306X

-
Output Current:
-
Output Voltage:
-
DC Supply Type:
-
Number Output:
Programmable Linear DC Power Supply Siglent SPD4121X

-
Output Current:
-
Output Voltage:
-
DC Supply Type:
-
Number Output:
Programmable Linear DC Power Supply Siglent SPD4323X
Please login to write review!