AC mΩ Meter Megaohm Tsuruga 356M
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: sales@lidinco.com
- Add: 487 Cong Hoa Street, Tan Binh Ward, Ho Chi Minh City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: bn@lidinco.com
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh, Vietnam
-
Technical Counseling
100% Free
-
Free Shipping
For 3.000.000vnd Order
Specification
Data is being updated
Description
- Internal resistance of Battery, contact resistance etc.
Model Designation
| MODEL | THE NUMBER OF CH | |
|---|---|---|
| 356M-05 | 5CH | Extension unit NOT available |
| 356M-10 | 10CH | |
| 356M-15 | 15CH | |
| 356M-20 | 20CH | Extension unit available |
| MODEL | CH NUMBER OF EXTENSION |
|---|---|
| 5811-71-05 | 5CH |
| 5811-71-10 | 10CH |
| 5811-71-15 | 15CH |
| 5811-71-20 | 20CH |
Specifications
| MEASUREMENT RANGE NOTE 1 | 30 mΩ | 300 mΩ | 3 Ω |
|---|---|---|---|
| RESOLUTION | 1 μΩ | 10 μΩ | 100 μΩ |
| MEASURING CURRENT | 7.4 mA | 1 mA | 100 μA |
| ACCURACY NOTE 2 | ± (0.5 % of rdg. + 8 dgt.) | ||
| TEMPERATURE COEFFICIENT | ± (0.05 % of rdg. + 0.8 dgt.) / ℃ | ||
| OPEN TERMINAL VOLTAGE | Less than 20 mV peak (with OFF function) | ||
| MEASUREMENT RANGE NOTE 1 | ± 5 V | ± 50 V |
|---|---|---|
| RESOLUTION | 100 μV | 1 mV |
| ACCURACY NOTE 2 | ± (0.05 % of rdg. + 5dgt.) | |
| TEMPERATURE COEFFICIENT | ± (0.005 % of rdg. +0.5 dgt.) / ℃ | |
| MEASURING METHOD | AC 4 terminal method (Resistance measurement) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MEASURING FREQUENCY | AC 1 kHz ± 20 Hz (Resistance measurement) | |||||||||||
| SAMPLING CYCLE | 10 times / s. (Resistance, voltage measurement) | |||||||||||
| MEASUREMENT TERMINAL | Connector of 2.54 mm pitch, MIL-C-86503 standard | |||||||||||
| WIRING RESISTANCE | Source side: Less than 0.1 Ω | |||||||||||
| DISPLAY | LCD display Resistance measurement: 35000 Voltage measurement: 50000 (with polarity indication) | |||||||||||
| MEASURING MODE |
| |||||||||||
| MEASURING TIME (DURING AUTOMATIC MEASUREMENT) | Select 1 s. or 2 s. for one CH Measuring time of 1 s.:aprx. 900 ms., 2 s.: aprx.1900 ms. | |||||||||||
| JUDGMENT | Upper limit (H1, H2) can be set.
| |||||||||||
| INSULATION RESISTANCE | DC 500 V, more than 50 MΩ | |||||||||||
| WITHSTANDING VOLTAGE | AC 1500 V, 1 min. | |||||||||||
| POWER SUPPLY TOLERANCE | AC 90 to 250 V (356M, 5811-71) | |||||||||||
| OPERATING AMBIENT TEMPERATURE | 0 to 50 ℃ | |||||||||||
| STORAGE TEMPERATURE | -20 to 70 ℃ | |||||||||||
| WEIGHT | 356M aprx. 1 kg, 5811-71 aprx. 1 kg | |||||||||||
| DIMENSION | 205 (W) x 64 (H) x 169 (D) mm | |||||||||||
| SERIAL COMMUNICATION RS-232C |
| |||||||||||
| ACCESSORY |
| |||||||||||
| ||||||||||||
| MEASUREMENT CABLE | Not included, manufacturable based on meeting with us. |