Digital Oscilloscope LeCroy WaveRunner 640Zi 4 GHz, 4 CH

Digital Oscilloscope LeCroy WaveRunner 640Zi 4 GHz, 4 CH

SKU:
640Zi
Brand:
Warranty:
N/A
Price: Contact
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Data is being updated

Máy hiện sóng, Oscilloscope LeCroy WaveRunner 640Zi 4 GHz, 4 CH

Máy hiện sóng  LeCroy WaveRunner 640Zi băng thông 4 GHz, lấy mẫu 20 GSa/s, 4 kênh, bộ nhớ 16 Mpts/kênh, màn hình 12.1 inch.

Superior Validation, Debug, Analysis

The WaveRunner 6 Zi defines superiority in a test instrument. The powerful feature set includes a wide range of application packages, advanced triggering to isolate events, a user interface developed for quick and easy navigation, a wide range of probing options, and lightning-fast performance.

Most Comprehensive Serial Data Analysis

WaveRunner 6 Zi offers the most tools for serial data analysis. With over 17 trigger, decode, and compliance solutions, WaveRunner 6 Zi can address problems with unique, powerful views and automated tools. The unique measurement toolset, ProtoSync, combines the oscilloscope view with a simultaneous view of data link layer decodes on the same instrument.

Excellent Signal Fidelity

The WaveRunner 6 Zi oscilloscope family features a pristine signal path that offers unmatched signal fidelity with low noise. This performance is augmented by a huge offset and timebase delay adjustment to allow easy signal and amplifier performance assessment and zooming on vertical and horizontal signal characteristics.


A New Way to Navigate and View

The WavePilot control area provides convenient control of Cursors, Decode, WaveScan, History, LabNotebook, and Spectrum by their respective function buttons on the front panel.

The SuperKnob is a joystick-like knob in the center of the WavePilot control area used to easily navigate through tables, zoom and position waveforms, and quickly document and annotate your setups.

Simply slide the button on the left side of the display and rotate upwards 90º. The display will automatically change from landscape to portrait mode. The display will also pivot upwards and downwards to optimize viewing angle.


More Trigger Capability Isolates More Problems More Quickly

A powerful combination of high bandwidth edge and 10 different SMART triggers, four stage cascade triggering, measurement trigger, and TriggerScan are all standard and allow you to isolate the problem quickly and begin focus on the cause. The measurement trigger offers a powerful option to qualify a trigger event based on a qualified measurement with great resolution. A high-speed serial trigger enables triggering on up to 3 Gb/s serial patterns of up to 80-bits in length. A full range of serial triggers (I2C, SPI, UART, RS-232, Audio (I2S, LJ, RJ, TDM), CAN, LIN, FlexRay, MIL-STD-1553, SATA, 8b/10b, USB2 and many others) are also available.


Rotating Display

The 12.1" high resolution WXGA wide screen is designed to provide the best view of any signal type on the display.

The widescreen is ideal for a variety of signals where long records are required and zooming or scrolling results in a large block of data.

Rotate the screen 90° degrees to optimize the display for viewing digital signals, jitter tracks, eye diagrams, and frequency plots. The screen image will adjust automatically when rotated. Tilt the display up or down in either orientation to minimize reflections or glare.

Vertical System

Bandwidth4 GHz
Analog Bandwidth (Max)4 GHz
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input)4 GHz (≥ 5 mV/div)
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input)500 MHz (typical)
Rise Time (10-90%, 50 Ω)100 ps (typical)
Rise Time (20-80%, 50 Ω)75 ps (typical)
Input Channels4
Bandwidth Limiters20MHz, 200MHz, 1GHz
Input Impedance50 Ω+/-2% or 1 MΩ||17pF, 10 MΩ || 9.5 pF with supplied Probe
Input Coupling1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Maximum Input Voltage50 Ω: 5V RMS ± 10V peak 1 MΩ: 400 V max. (DC + peak AC < 10 kHz)
Channel-Channel Isolation> 100:1 up to 2.5GHz > 30:1 from 2.5GHz to rated BW
Vertical Resolution8 bits; up to 11 bits with enhanced resolution (ERES)
Sensitivity50 Ω: 1 mV-1 V/div, fully variable; 1 MΩ: 1 mV-10 V/div, fully variable
DC Vertical Gain Accuracy (Gain Component of DC Accuracy)±(0.5%) F.S, offset at 0 V
Offset Range50 Ω BWL≤1 GHz ±1.6 V @ 2 mV - 4.95 mV/div ±4 V @ 5 mV - 9.9 mV/div ±8 V @ 10 mV - 19.8 mV/div ±10 V @ 20 mV - 1V/div BWL>1GHz ±1.4V @ 5 mV - 122 mV/div ±10V @ 124 mV - 1 V/div1 MΩ ±1.6 V @ 2 mV - 4.95 mV/div ±4 V @ 5 mV - 9.9 mV/div ±8 V @ 10 mV - 19.8 mV/div ±16 V @ 20 mV - 140 mV/div ±80 V @ 142 mV - 1.4 V/div ±160 V @ 1.42 V - 10V/div
DC Vertical Offset Accuracy±(1.5% of offset setting +1% of full scale + 1 mV) (test limit)
 

Horizontal System

TimebasesInternal timebase common to 4 input channels; an external clock may be applied at the auxiliary input
Time/Division Range20 ps/div - 1.6 ks/div with standard memory (up to 3.2 ks/div with -S memory, 6.4 ks/div with -M memory) RIS available at ≤ 10 ns/div; Roll Mode available at ≥ 100 ms/div and ≤ 5 MS/s
Clock Accuracy<=1.5 ppm +(aging of 0.5 ppm/yr from last calibration)
Trigger and Interpolator Jitter≤ 2 ps RMS (typical) <0.1 ps RMS (typical, software assisted)
External Timebase Reference (Input)10MHz +/-25ppm into 50 ohms (requires Lbus BNC adaptor)
External Timebase Reference (Output)10MHz, 3.5 dBm +/-1dBm, syncronized to reference being used (internal or external reference) via LBUS BNC adaptor
External ClockDC to 100 MHz; (50 Ω/1 MΩ), EXT BNC input, Minimum rise time and amplitude requirements apply at low frequencies.
 

Acquisition System

Sample Rate20 GS/s on 4 Ch 40 GS/s on 2 Ch
Single-Shot Sample Rate/Ch20 GS/s on 4 Ch 40 GS/s on 2 Ch
Random Interleaved Sampling (RIS)200 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Maximum Trigger Rate1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Intersegment Time1 µs
Maximum Acquisition Memory128 Mpts (2 Ch operation)
Standard Memory (4 Ch / 2 Ch / 1Ch) (Number of Segments)16M / 32M / 32M (5,000)
Memory Options (4 Ch / 2 Ch / 1Ch) (Number of Segments)S-32 Option: 32M / 64M / 64M (15,000) M-64 Option: 64M / 128M / 128M (15,000)
 

Acquisition Processing

AveragingSummed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES)From 8.5 to 11 bits vertical resolution
Envelope (Extrema)Envelope, floor, or roof for up to 1 million sweeps
InterpolationLinear or Sin x/x
 

Triggering System

ModesNormal, Auto, Single, and Stop
SourcesAny input channel, Ext, Ext/10, or line; slope and level unique to each source (except line trigger)
Coupling ModeDC, AC, HFRej, LFRej
Pre-trigger Delay0-100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay0-10,000 Divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off by Time or EventsFrom 2 ns up to 20 s or from 1 to 99,999,999 events
Internal Trigger Range±4.1 div from center (typical)
Trigger Sensitivity with Edge Trigger ProBus Inputs2 div @ < 4 GHz 1.5 div @< 2 GHz 1 div @ < 200 MHz 0.9 div @<10 MHz (DC, AC, and LFRej coupling, ≥ 10 mV/div, 50 Ω)
External Trigger Sensitivity, (Edge Trigger)2 div @ 1 GHz 1.5 div @ < 500 MHz 1 div @ <200 MHz 0.9 div @<10 MHz (DC, AC, and LFRej coupling)
Max. Trigger Frequency, SMART Trigger2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps)
External Trigger Input RangeExt (±0.4 V); Ext/10 (±4 V)
 

Basic Triggers

EdgeTriggers when signal meets slope (positive, negative, or either) and level condition.
WindowTriggers when signal exits a window defined by adjustable thresholds
TV-Composite VideoTriggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
 

SMART Triggers

State or Edge QualifiedTriggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Qualified FirstIn Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events.
DropoutTriggers if signal drops out for longer than selected time between 1 ns and 20 s.
PatternLogic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don?t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
 

SMART Triggers with Exclusion Technology

GlitchTriggers on positive or negative glitches with selectable widths. minimum width 1.5ns, Maximum Width: 20s
Width (Signal or Pattern)Triggers on positive or negative glitches with selectable widths. minimum width 1.5ns, Maximum Width: 20s
Interval (Signal or Pattern)Triggers on intervals selectable between 1 ns and 20 s.
Timeout (State/Edge Qualified)Triggers on any source if a given state (or transition edge) has occurred on another source. Delay between sources is 1 ns to 20 s, or 1 to 99,999,999 events.
RuntTrigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew RateTrigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
Exclusion TriggeringTrigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
 

Cascade (Sequence) Triggering

CapabilityArm on "A" event, then Trigger on "B" event. Or Arm on "A" event, then Qualify on "B" event, and Trigger on "C" event.
TypesCascade A then B: Edge, Window, Pattern (Logic) Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage B only. Cascade A then B then C (Measurement): Edge, Window, Pattern (Logic), Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage C only. Cascade A then B then C: Edge, Window, Pattern (Logic)
HoldoffHoldoff between A and B or B and C is selectable by time (1ns to 20s) or number of events. Measurement trigger selection as the last stage in a Cascade precludes a holdoff setting between the prior stage and the last stage.
 

High Speed Serial Protocol Triggering

Data Rates(Option WR6Zi-80B-8B10B TD) 150 Mb/s - 3 Gb/s
Pattern Length80 bits, NRZ or 8b10b
Clock Recovery Jitter1 ps rms + 0.3% Unit Interval rms for PRBS data patterns with 50% transition density
Hardware Clock Recovery Loop BWPLL Loop BW = Fbaud/5500, 100 Mb/s to 2.488 Gb/s (typical)
 

Low Speed Serial Protocol Triggering (Optional)

Optionally availableI2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay, MIL-STD-1553, USB 1.x/2.0, AudioBus, SATA
 

Measurement Trigger

Measurement Trigger CapabilitySelect from a large number of measurement parameters trigger on a measurement value with qualified limits. Can be used as only trigger or last event in a Cascade Trigger.
 

Color Waveform Display

TypeColor 12.1" widescreen flat panel TFT-Active Matrix with high resolution touch screen
ResolutionWXGA; 1280 x 800 pixels.
Number of tracesDisplay a maximum of 16 traces. Simultaneously display channel, zoom, memory and math traces.
Grid StylesAuto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y
Waveform RepresentationSample dots joined, or sample dots only
 

Internal Waveform Memory

Internal Waveform Memory4 active waveform memory traces (M1-M4) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

Integrated Second Display

TypeSupports touch screen integration of user-supplied second display with split-grid capability.
Resolution(Note: touch screen driver for second display may not be a Fujitsu driver)
 

LeCroy WaveStream™ Fast Viewing Mode

Intensity256 Intensity Levels, 1-100% adjustable via front panel control
TypesSelect analog or color-graded
Number of Channelsup to 4 simultaneously
Max Sampling Rate20 GS/s (40 GS/s when interleaved)
Persistence AgingSelect from 500 ms to Infinity
Waveforms/second (continuous)up to 2500 Waveforms/second
OperationFront panel toggle between WaveStream ON (Analog), ON (Color) and OFF
 

Analog Persistence Display

Analog and Color-Graded PersistenceVariable saturation levels; stores each trace?s persistence data in memory
Persistence TypesSelect analog, color, or three-dimensional
Trace SelectionActivate persistence on all or any combination of traces
Persistence AgingSelect from 500 ms to infinity
Sweep Display ModesAll accumulated, or all accumulated with last trace highlighted
 

Processor/CPU

TypeIntel Core i5, 2.5 GHz (or better)
Processor Memory2 GB standard, up to 4GB optional
Operating SystemMicrosoft Windows® 7 Pro 64 bit Embedded
Real Time ClockDate and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Zoom Expansion Traces

Zoom Expansion TracesDisplay up to 8 Zoom and 8 Math/Zoom traces
 

Setup Storage

Front Panel and Instrument StatusStore to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Interface

Remote ControlVia Windows Automation, or via LeCroy Remote Command Set
Network Communication StandardVXI-11 or VICP, LXI Class C (v1.2) Compliant
GPIB PortSupports IEEE - 488.2 (External)
Ethernet PortSupports 2 10/100/1000BaseT Ethernet interface (RJ45 ports)
USB PortsMinimum 6 total (incl. 2 front panel) USB 2.0 ports support Windows compatible devices
USB Device Port1 USBTMC port
External Monitor Port15 pin D-Type WXGA compatible DB-15 to support customer-supplied external monitor. Includes support for extended desktop operation with WXGA resolution on second monitor.
Peripheral BusLeCroy LBUS standard
 

Auxiliary Input

Signal TypesSelect External Trigger or External Clock Input on the front panel
Coupling50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage50 Ω: 5 Vrms; 1 MΩ: 250 Vmax (DC + Peak AC ≤ 10 kHz)
 

Auxiliary Output

Signal TypesSelect from control signals or Off
Output Signal500 Hz-1 MHz square wave or DC level; 50 mV-1 V into 1 MΩ
Control SignalsTrigger enabled, trigger out, pass/fail status, off
Connector TypeBNC, located on rear panel
 

Automatic Setup

Auto SetupAutomatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical ScaleAutomatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

General

Auto CalibrationEnsures specified DC and timing accuracy is maintained for 1 year minimum.
 

Probes

ProbesQty. (4) ÷10 Passive Probes
Probe SystemProbus. Automatically detects and supports a variety of compatible probes
Scale FactorsAutomatically or manually selected depending on probe used
Calibration OutputDefault is 1kHz square wave, 1Vp-p (typical), output to probe hook. Settable from 250 Hz to 1 MHz square wave; 50 mV to 1.0V.
 

Power Requirements

Voltage100-240 VAC ±10% at 45-66 Hz; 110-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection; Installation Category 300 V CAT II
Max. Power Consumption500 VA
 

Environmental and Safety

Temperature (Operating)+5 °C to +40 °C
Temperature (Non-Operating)-20 °C to +60 °C
Humidity (Operating)5% to 80% relative humidity (non-condensing) up to +31 °C. Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating)5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating)Up to 10,000 ft. (3048 m) at or below +25 °C
Altitude (Non-Operating)Up to 40,000 ft. (12,192 m)
Random Vibration (Operating)0.31 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating)2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock30 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Physical Dimensions

Dimensions (HWD)11.69"H x 16.46"W x 8.94"D (297 x 418 x 227 mm)
Weight25.4 lbs. (11.5 kg)
Shipping Weight39 lbs. (17.7 kg)

Accessories

Micsig TO1152 150MHz Tablet Oscilloscope

Contact

Digital Multimeter Matrix MDM-8165A

Contact

Digital Multimeter Matrix MDM-8165

Contact

1-Door Large Sheet Steel Safety Cabinet ALT155

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG500

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG350

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG200

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG120

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG80

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG60

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG30

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG40

Contact
Reviews & Comments

0.0/5

(0 ratings)
  • 5 0
  • 4 0
  • 3 0
  • 2 0
  • 1 0

Please login to write review!

Review about this product: