Digital Oscilloscope LeCroy HDO8038 350 MHz, 8 channel

Digital Oscilloscope LeCroy HDO8038 350 MHz, 8 channel

SKU:
HDO8038
Brand:
Warranty:
N/A
Price: Contact
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Data is being updated

Key Features
  • 8 input channels
  • 12-bit ADC resolution, up to 15 bits with enhanced resolution
  • 350 MHz, 500 MHz, and 1 GHz bandwidths
  • Long Memory - up to 250 Mpts/Ch
  • 12.1" touch screen display
  • DisplayPort 1.2 video output for Ultra HD extended desktop (UHD, 3840 x 2160 pixels)
  • Q-ScapeTM tabbed displays
  • Mixed Signal capability (16 digital channels, 1.25 GS/s sample rate)
  • Serial data trigger and decode
  • Powerful analysis capabilities
8 Analog + 16 Digital Input Channels

Capture 8 analog signals plus 16 digital logic signals. Get more information in one place at one time.
 

HD4096 High Definition Technology

HD4096 high definition technology enables oscilloscopes to capture and display signals of up to 1 GHz with high sample rate and 16 times more resolution than other oscilloscopes.

Benefits of HD4096 Technology

Waveforms captured and displayed on oscilloscopes with HD4096 technology are cleaner and crisper. Signal details often lost in the noise are clearly visible and easy to distinguish HD4096 enables oscilloscopes to deliver unmatched measurement precision for improved debug and analysis.

Motor Drive Power Analyzer software

Provides three-phase numerical and waveform power analysis from motor drive input through motor mechanical output. Included are real, apparent, and reactive power measurements, power factor and phase angle, efficiency, and various voltage and current parameters. Both two-wattmeter and three-wattmeter methods are supported, as well as line-line to line-neutral voltage conversion. Motor speed, position, and torque integration are the most complete available. Turn your HDO8000 into a complete measurement and debug tool for the motor, motor drive, and embedded motor control system.

Q-Scape Multi-Tab Display Architecture

More waveforms requires new display architectures. Unique Q-Scape multi-tab display architecture speeds your understanding of your design with 4x the display area. Quickly move waveforms to different tabs through drag-and-drop.

Ultra HD (UHD, 3840 x 2160 pixel) Extended Desktop

Utilize the DisplayPort 1.2 video output in Extended Desktop mode to maximize display size and screen resolution. Split grids amongst the scope and external display. Purchase an external display that is touchscreen compatible and gain even more flexibility.

Powerful Analysis Capabilities

Up to 250 Mpts/ch of acquisition memory allows many seconds of data capture. Display up to 40 waveforms (12 math, 12 zoom, 12 memory) and 12 measurement parameters. Most powerful motherboard in its class - Intel Intel Core i5-4570s Quad (core), 2.9 GHz (per core), up to 32 GB of RAM.

 

Vertical System

Analog Bandwidth (Max)350 MHz
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input)350 MHz (≥1 mV/div)
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input)350 MHz (typical)
Rise Time (10-90%, 50 Ω)1 ns (typical)
Input Channels8
Bandwidth Limiters20MHz, 200MHz
Input Impedance1 MΩ ± 2.0% || 16 pF, 50 Ω ± 2.0%
Input Coupling1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Maximum Input Voltage50 Ω: 5 Vrms, 1 MΩ: 400 V max (DC + Peak AC ≤ 10 kHz)
Channel-Channel IsolationDC-400MHz: 60 dB (>1000:1), 400MHz up to rated BW: 50 dB (>300:1), (For any two ProBus input channels, same v/div settings, typical)
Vertical Resolution12 bits; up to 15 bits with enhanced resolution (ERES)
Sensitivity50 Ω: 1 mV-1 V/div, fully variable; 1 MΩ: 1 mV-10 V/div, fully variable
DC Vertical Gain Accuracy (Gain Component of DC Accuracy)±(0.5%) F.S, offset at 0 V
Offset Range50Ω +/-1.6V: 1mV/div-4.95mV/div +/-4V: 5mV/div-9.9mV/div +/-8V: 10mV/div-19.8mV/div +/-10V: 20mV/div-1V/div1MΩ +/-1.6V: 1mV/div-4.95mV/div +/-4V: 5mV/div-9.9mV/div +/-8V: 10mV/div-19.8mV/div +/-16V: 20mV/div-100mV/div +/-80V: 102mV/div-198mV/div /-160V: 200mV/div-1V/div +/-400V: 1.02V/div-10V/div
Offset Accuracy+/-(1.0% of offset value + 0.5%FS + 0.02% of max offset + 1mV)
DC Vertical Offset Accuracy±(1.0% of offset setting + 0.5%FS + 0.02% of max offset + 1mV)
 

Horizontal System

TimebasesInternal timebase common to 8 input channels; an external clock may be applied at the auxiliary input for acquisition of channels 1-4 (channels 5-8 disabled)
Time/Division Range20 ps/div - 5 ks/div with standard memory (up to 10 ks/div with -L memory, 25 ks/div with -XL memory); RIS available at ≤ 10 ns/div; Roll Mode available at ≥ 100 ms/div and ≤ 5 MS/s
Clock Accuracy+/-2.5ppm + 1.0ppm/year from calibration
Trigger and Interpolator Jitter≤ 4.0 psrms (typical) <0.1 ps RMS (typical, software assisted)
Channel-Channel Deskew Range±9 x time/div. setting, 100 ms max., each channel
External Timebase Reference (Input)10MHz +/-25ppm at 0 to 10dBm into 50Ohms
External Timebase Reference (Output)10MHz, 3.5 dBm +/-1dBm, syncronized to reference being used (internal or external reference) via LBUS BNC adaptor
External ClockDC to 100 MHz; (50 Ω/1 MΩ), EXT BNC input, for acquisition of channels 1-4 (channels 5-8 disabled). Minimum rise time and amplitude requirements apply at low frequencies.
 

Acquisition System

Single-Shot Sample Rate/Ch2.5 GS/s on 8 Ch
Random Interleaved Sampling (RIS)125 GS/s, user selectable for repetitive signals (20 ps/div to 10 ns/div)
Maximum Trigger Rate1,000,000 Triggers/sec (in Sequence Mode, up to 8 channels)
Intersegment Time1 µs
Standard Memory (4 Ch / 2 Ch / 1Ch) (Number of Segments)50M/50M/50M (30,000)
Memory Options (4 Ch / 2 Ch / 1Ch) (Number of Segments)L- Option: 100M / 100M / 100M (60,000) XL - Option: 250M / 250M / 250M (65,000)
 

Acquisition Processing

AveragingSummed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES)From 12.5 to 15 bits vertical resolution
Envelope (Extrema)Envelope, floor, or roof for up to 1 million sweeps
InterpolationLinear or Sin x/x
 

Triggering System

ModesNormal, Auto, Single, and Stop
SourcesAny input channel, Ext, Ext/10, or line; slope and level unique to each source (except line trigger)
Coupling ModeDC, AC, HFRej, LFRej
Pre-trigger Delay0-100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay0-10,000 Divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off by Time or EventsFrom 2 ns up to 20 s or from 1 to 99,999,999 events
Internal Trigger Range±4.1 div from center (typical)
Trigger Sensitivity with Edge Trigger ProBus Inputs0.9 division: 10 MHz 1.0 divisions: 200 MHz 2.0 divisions: 350 MHz
External Trigger Sensitivity, (Edge Trigger)2.0 div @ <350 MHz 1.0 div @ <200 MHz 0.9 div @ <10 MHz
Max. Trigger Frequency, SMART Trigger350MHz
External Trigger Input RangeExt (±0.4 V); Ext/10 (±4 V)
 

Basic Triggers

EdgeTriggers when signal meets slope (positive, negative, or either) and level condition.
WindowTriggers when signal exits a window defined by adjustable thresholds
TV-Composite VideoTriggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
 

SMART Triggers

State or Edge QualifiedTriggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events. (Note: event B pattern trigger cannot include analog channels).
Qualified FirstIn Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events. (Note: event B pattern trigger cannot include analog channels).
DropoutTriggers if signal drops out for longer than selected time between 1 ns and 20 s.
PatternLogic combination (AND, NAND, OR, NOR) of up to 9 inputs (8 channels and external trigger input). Each source can be high, low, or don't care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
 

SMART Triggers with Exclusion Technology

GlitchTriggers on positive or negative glitches with selectable widths. minimum width 1.5ns, Maximum Width: 20s
Width (Signal or Pattern)Triggers on positive or negative glitches with selectable widths. minimum width 1.5ns, Maximum Width: 20s
Interval (Signal or Pattern)Triggers on intervals selectable between 1 ns and 20 s.
Timeout (State/Edge Qualified)Triggers on any source if a given state (or transition edge) has occurred on another source. Delay between sources is 1 ns to 20 s, or 1 to 99,999,999 events.
RuntTrigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew RateTrigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
Exclusion TriggeringTrigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
 

Low Speed Serial Protocol Triggering (Optional)

Optionally availableI2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN1.1, CAN2.0, CAN FD, LIN, FlexRay, MIL-STD-1553, AudioBus (I2S, LJ, RJ, TDM), USB1.x/2.0
 

Measurement Trigger

Measurement Trigger CapabilitySelect from a large number of measurement parameters. Trigger on a measurement value with qualified limits.
 

Color Waveform Display

TypeColor 12.1" widescreen flat panel TFT-Active Matrix with high resolution touch screen
ResolutionWXGA; 1280 x 800 pixels.
Number of tracesDisplay a maximum of 40 traces. Simultaneously display channel, zoom, memory and math traces.
Grid StylesAuto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y, Tandem, Quattro, Twelve, Sixteen
Waveform RepresentationSample dots joined, or sample dots only
 

Internal Waveform Memory

Internal Waveform Memory12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

Integrated Second Display

TypeSupports touch screen integration of user-supplied second display with split-grid capability. (Note: touch screen driver for second display may not be a Fujitsu driver)
ResolutionUp to Ultra HD (UHD) 3840 x 2160 pixels using DisplayPort 1.2 output
 

Analog Persistence Display

Analog and Color-Graded PersistenceVariable saturation levels; stores each trace's persistence data in memory
Persistence TypesSelect analog, color, or three-dimensional
Trace SelectionActivate persistence on all or any combination of traces
Persistence AgingSelect from 500 ms to infinity
Sweep Display ModesAll accumulated, or all accumulated with last trace highlighted
 

High Speed Digitizer Output (Option)

Type0
Transfer Rate0
Output Protocol0
Control Protocol0
Command Set0
 

Processor/CPU

TypeIntel® CoreTM i5-4570S Quad, 2.9 GHz (3.6 GHz in turbo mode) (or better)
Processor Memory8 GB standard for standard memory (50 Mpt) with 32 GB optional. 32 GB standard for -L and -VL memory options.
Operating SystemMicrosoft Windows® 7 Pro 64 bit Embedded
Real Time ClockDate and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Zoom Expansion Traces

Zoom Expansion TracesDisplay up to 12 Zoom and 12 Math/Zoom traces
 

Setup Storage

Front Panel and Instrument StatusStore to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Interface

Remote ControlVia Windows Automation, or via LeCroy Remote Command Set
GPIB PortSupports IEEE - 488.2 (External)
LSIB Port (optional)0
Ethernet PortSupports 2 10/100/1000BaseT Ethernet interface (RJ45 ports)
USB PortsMinimum 6 total: 2 front panel USB2.0 and 4 rear-mounted USB3.0 support Windows compatible devices
USB Device Port1 USBTMC port
External Monitor PortDisplayPort 1.2 compatible to support customer-supplied external monitor. Includes support for extended desktop operation with Ultra HD (UHD) 3840 x 2160 pixel resolution and split-grid capability on external monitor. Supports touch screen integration of external monitor (Note: external display can not use a Fujitsu touch-screen driver).
Serial Port0
 

Auxiliary Input

Signal TypesSelect External Trigger or External Clock Input on the front panel
Coupling50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage50 Ω: 5 Vrms; 1 MΩ: 400 Vmax (DC + Peak AC ≤ 5 kHz)
 

Auxiliary Output

Signal TypesSelect from control signals or Off
Output Signal500 Hz-1 MHz square wave or DC level; 50 mV-1 V into 1 MΩ
Control SignalsTrigger enabled, trigger out, pass/fail status, off
Connector TypeBNC, located on rear panel
 

Automatic Setup

Auto SetupAutomatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical ScaleAutomatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Probes

ProbesQty. (4) ÷10 Passive Probes
Probe SystemProBus. Automatically detects and supports a variety of compatible probes
Scale FactorsAutomatically or manually selected depending on probe used
Calibration OutputDefault is 1kHz square wave, 1Vp-p (typical), output to probe hook. Settable from 250 Hz to 1 MHz square wave; 50 mV to 1.0V.
 

Power Requirements

Voltage100-240 VAC ±10% at 45-66 Hz; 110-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection; Installation Category 300 V CAT II
Nominal Power Consumption400 W / 420 VA
Max. Power Consumption550 W / 570 VA (with all PC peripherals and active probes connected to 8 channels)
 

Environmental and Safety

Temperature (Operating)+5 °C to +40 °C
Temperature (Non-Operating)-20 °C to +60 °C
Humidity (Operating)5% to 80% relative humidity (non-condensing) up to +31 °C. Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating)5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating)Up to 10,000 ft. (3048 m) at or below +25 °C
Altitude (Non-Operating)Up to 40,000 ft. (12,192 m)
Random Vibration (Operating)0.31 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating)2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock30 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Physical Dimensions

Dimensions (HWD)14.72"H x 16.41"W x 11"D (374 mm x 417 mm x 280 mm)
Weight12.27 kg. (27 lbs.)

Accessories

Micsig TO1152 150MHz Tablet Oscilloscope

Contact

Digital Multimeter Matrix MDM-8165A

Contact

Digital Multimeter Matrix MDM-8165

Contact

1-Door Large Sheet Steel Safety Cabinet ALT155

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG500

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG350

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG200

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG120

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG80

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG60

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG30

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG40

Contact
Reviews & Comments

0.0/5

(0 ratings)
  • 5 0
  • 4 0
  • 3 0
  • 2 0
  • 1 0

Please login to write review!

Review about this product: