Specification

Data is being updated

 

Máy hiện sóng, Oscilloscope LeCroy HDO4022-MS 200 MHz, 2 CH, 16 digital CH

Máy hiện sóng  LeCroy HDO4022-MS băng thông 200 MHz, lấy mẫu 2.5 GSa/s, 2 + 16 kênh, bộ nhớ 12.5 Mpts/kênh, màn hình cảm ứng 12.1 inch.

Key Features
  • 12-bit ADC resolution, up to 15 bit with enhanced resolution
  • 200 MHz, 350 MHz, 500 MHz, 1 GHz bandwidths
  • Long Memory – up to 25 Mpts/Ch (50 Mpts interleaved)
  • 12.1” touch screen display
  • WaveScan – Advanced Search and Find
  • LabNotebook Documentation and Report Generation
  • History Mode – Waveform Playback
  • Spectrum Analyzer Mode
  • Power Analysis Software
  • Serial Data Trigger and Decode
  • 16 Digital Channels with 1.25 GS/s Sample Rate
  • Mixed Signal Debug Capabilities
    • Analog and Digital Cross Pattern Triggering
    • Digital Pattern Search and Find
    • Analog and Digital Timing Measurements
    • Activity Indicators
HD4096 High Definition Technology

HD4096 high definition technology enables oscilloscopes to capture and display signals of up to 1 GHz with high sample rate and 16 times more resolution than other oscilloscopes.

Benefits of HD4096 Technology

Waveforms captured and displayed on oscilloscopes with HD4096 technology are cleaner and crisper. Signal details often lost in the noise are clearly visible and easy to distinguish HD4096 enables oscilloscopes to deliver unmatched measurement precision for improved debug and analysis.

Mixed Signal - No Compromises

Debug complex embedded designs with integrated 16 channel mixed signal capability

Identify and Isolate Problems Fast

Quickly locate analog or digital waveforms for runts, glitches or other anomolies with WaveScan

History Mode Waveform Playback

Scroll back in time to isolate anomalies and quickly find the source of the problem.

Touch Screen Simplicity

Easily control channels, trigger, math and measurements with the large multi-touch display and intuitive interface.

Sequence Mode

Capture many fast pulses in quick succession or events separated by long periods of time.

Serial Bus Trigger and Decode

View decoded protocol information on top of physical layer waveforms and trigger on protocol specific messages

Save, Document, Report

Save all results and data with a single button press and create custom reports with LabNotebook

Simple Power Measurements

Measure and analyze operating characteristics of power conversion devices and circuits

Spectrum Analyzer Interface

View signal details in the frequency domain with a spectrum analyzer style user interface

Advanced Math and Measure

Use automatic measurement parameters and math functions to understand every waveform detail

Cross Triggering

Flexible analog and digital cross-pattern triggering across all 20 channels

Digital Timing Measurements

Perform timing measurements on digital signals and analyze with trends, statistics and histicons

Parallel Pattern Search

Find a digital pattern across many digital lines using the parallel pattern search capability of WaveScan

Activity Indicators

Quickly see the state of all the digital lines at the same time using convenient activity indicators.

 

Vertical System

Rise time1.75 ns
Bandwidth200 MHz
Input Channels2
Bandwidth Limiters20 MHz
Input Impedance1 MΩ ± 2.0% || 15 pF, 50 Ω ± 2.0%
Input Coupling1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Maximum Input Voltage"50 Ω: 5 Vrms, 1 MΩ: 400 V max (DC + Peak AC ≤ 10 kHz)"
Channel-Channel Isolation"DC-400MHz: 60 dB (>1000:1), 400MHz up to rated BW: 50 dB (>300:1), (For any two ProBus input channels, same v/div settings, typical)"
Vertical Resolution12 bits; up to 15 bits with enhanced resolution (ERES)
Sensitivity"50 Ω: 1 mV-1 V/div, fully variable; 1 MΩ: 1 mV-10 V/div, fully variable 50 ?: 1 mV/div - 1 V/div"
DC Gain Accuracy±(0.5%) F.S, offset at 0 V
Offset Range50Ω +/-1.6V: 1mV/div-4.95mV/div +/-4V: 5mV/div-9.9mV/div +/-8V: 10mV/div-19.8mV/div +/-10V: 20mV/div-1V/div1MΩ +/-1.6V: 1mV/div-4.95mV/div +/-4V: 5mV/div-9.9mV/div +/-8V: 10mV/div-19.8mV/div +/-16V: 20mV/div-100mV/div +/-80V: 102mV/div-198mV/div +/-160V: 200mV/div-1V/div +/-400V: 1.02V/div-10V/div
 

Horizontal System

Time/Division Range200 ps/div - 1.25 ks/div with standard memory (up to 2.5 ks/div with -L memory); RIS available at <= 10 ns/div; Roll Mode available at >= 100 ms/div and <= 5 MS/s
Clock Accuracy±2.5ppm for 5 to 40C + 1.0ppm/year from calibration
Trigger and Interpolator Jitter4.5 ps (rms)
 

Acquisition System

Single-Shot Sample Rate/Ch2.5 GS/s
Equivalent Sample Rate125 GS/s
Memory25 Mpts/Ch on 1 Ch 12.5 Mpts/Ch on 2 Ch
 

Acquisition Modes

AveragingUp to 1,000,000
Peak Detectna
InterpolationLinear, Sin x/x
Enhanced ResolutionUp to 15 bits
Sequence ModeUp to 10,000 segments
 

Digital - Vertical and Acquisition

Input Channels16
Threshold GroupingsPod 2: D15 - D8, Pod 1: D7 - D0
Threshold SelectionsTTL, ECL, CMOS (2.5 V, 3.3 V, 5 V), PECL, LVDS or User Defined
Maximum Input Voltage±30V Peak
Threshold Accuracy±(3% of threshold setting + 100mV)
Input Dynamic Range±20V
Minimum Input Voltage Swing400mV
Input Impedance (Flying Leads)100 kΩ || 5 pF
Maximum Input Frequency250 MHz
Sample Rate1.25 GS/s
Record LengthStandard STD: 25MS - 16 Channels Optional -L: 50MS - 16 Channels
Minimum Detectable Pulse Width2 ns
Channel-to-Channel Skew350ps
User defined threshold range±10V in 20mV steps
User defined hysteresis range100 mV to 1.4 V in 100 mV steps
 

Triggering System

ModesNormal, Auto, Single, Stop
SourcesCh 1 - Ch 4, EXT, EXT/10, AC Line
Coupling ModeAC, DC, LF Rej, HF Rej
Pre-trigger Delay0 - 100% Full Scale
Post-trigger Delay0 - 10,000 Divisions
Hold-off by Time or Events2 ns up to 20s
Internal Trigger Range±4.1 Divisions
Trigger Sensitivity0.9 division: 10 MHz 1.0 divisions: 100 MHz 2.0 divisions: 200 MHz
External Trigger Sensitivity0.9 division: 10 MHz 1.0 divisions: 100 MHz 2.0 divisions: 200 MHz
External Trigger Input RangeExt: ±0.4 V, EXT/10: ±4.0 V
 

Display

TypeColor Touch Screen 12.1" TFT-LCD
Resolution1280 x 800
Grid StylesYT, XY
 

Trigger Types

Standard TriggersEdge, Glitch, Width, Logic (Pattern), TV (NTSC, PAL, SECAM, HDTV), Runt, Slew Rate, Interval, Dropout, Qualified
Optional Advanced Triggersna
Optional Serial Data TriggersI2C, SPI, UART/RS-232, CAN, LIN, FlexRay, SENT, MIL-STD-1553, ARINC 429, Audio (I2S, LJ, RJ, TDM), USB, USB-HSIC, MIPI D-PHY, DigRF3G
 

Internal Storage

Waveform Storage4 memory waveforms plus internal HDD
Setup Storage6 setups
 

Math

Number of Math Traces2
Standard Math FunctionsAdd, Subtract, Multiply, Divide, FFT, Absolute Value, Averaging (summed and continuous), Derivative, Envelope, Enhanced Resolution, Floor, Integral, Invert, Reciprocal, Rescale, Roof, Square, Square Root, Trend, Zoom
Optional Math Functionsna
 

Measurements

Number of Measurements Displayed8
Measurement ParametersAmplitude, Area, Base, Delay, Delta Period @ Level, Delta Time @ Level, Duty Cycle, Duty @ Level, Edge @ Level, Fall Time (90% - 10%), Fall Time (80% - 20%), Frequency, Frequency @ Level, Maximum, Mean, Minimum, Overshoot+, Overshoot-, Period, Peak-Peak, Period, Period @ Level, Phase, Rise Time (10% - 90%), Rise Time (20% - 80%), RMS, Skew, Standard Deviation, Time @ Level, Top, Width+, Width-
 

Interface

GPIB Port1 (optional)
USB (Device)1
Ethernet Port1
USB (Host)6
Serial Port0
 

Probes

ProbesQty. (4) ÷10 Passive Probes
Scale FactorsAutomatic/Manual: ÷1, ÷10, ÷20, ÷100, ÷200, ÷1000, ÷2000, ÷10000 Variable: (÷1x10-6 - ÷10000)
Calibration Output1 kHz square wave, 1.0 Vp-p, output to probe hook
 

Power Requirements

Voltage90 - 264 VAC, 45 HZ - 66 Hz 90 - 132 VAC, 380 HZ - 420 Hz
Max. Power Consumption330 VA
 

Environmental and Safety

Temperature (Operating)5 °C to 40 °C
Temperature (Non-Operating)-20 °C to 60 °C
Humidity (Operating)80% RH, 31 °C 50% RH, 40 °C
Humidity (Non-Operating)95% RH
Altitude (Operating)3,048 m max at <=30C
Altitude (Non-Operating)12,192 m
 

Physical Dimensions

Dimensions (HWD)291.7 mm x 399.4 mm x 131.31 mm (11.48" x 15.72" x 5.17")
Weight5.86 kg. (12.9 lbs.)

Accessories

Micsig TO1152 150MHz Tablet Oscilloscope

Contact

Digital Multimeter Matrix MDM-8165A

Contact

Digital Multimeter Matrix MDM-8165

Contact

1-Door Large Sheet Steel Safety Cabinet ALT155

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG500

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG350

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG200

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG120

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG80

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG60

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG30

Contact

Function / Arbitrary Waveform Generator Lecroy T3AFG40

Contact
Reviews & Comments

0.0/5

(0 ratings)
  • 5 0
  • 4 0
  • 3 0
  • 2 0
  • 1 0

Please login to write review!

Review about this product: