  • Voltage Range:
  • Accuracy:
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Data is being updated

Description

The Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.

Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.

Đồng hồ vạn năng Fluke 116

Features:

- Digital multimeter designed specifically for HVAC professionals
- Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)
- Provides microamps to test flame sensors
- Features low input impedance to helps prevent false readings due to ghost voltage
- Presents a large white LED backlight for working in poorly lit areas

Specifications: 

Thông số kỹ thuật - Specifications
Maximum voltage between any terminal and earth ground600 V
Surge protection6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to + 50°C
Storage temperature-40°C to + 60°C
Battery type9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life400 hours typical, without backlight
Accuracy Specifications
DC millivoltsRange/resolution600.0 mV / 0.1 mV
Accuracy±([% of reading] + [counts]): 0.5% + 2
DC voltsRange/resolution6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V
Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto voltsRange/resolution600.0 V / 0.1 V
Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMSRange/resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMSRange/resolution6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/resolution600 Ω / 1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
OhmsRange/resolution600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ
Accuracy0.9% + 1
Range/Resolution40.00 MΩ / 0.01 MΩ
Accuracy5% + 2
Diode TestRange/resolution2.00 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/resolution1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF
Accuracy1.9% + 2
Range/resolution> 1000 μF
Accuracy5% + 20%
Lo-Z CapacitanceRange1 nF to 500 μF
Accuracy10% + 2 typical
Temperature² (Type-K thermocouple)Range/resolution-40°C to 400°C / 0.1°C
Accuracy1% + 10²
Range/resolution-40°F to 752°F / 0.2°F
Accuracy1% + 18²
AC μA true-rms (45 Hz to 500 Hz)Range/resolution600.0 μA / 0.1 μA
Accuracy1.5% + 3
DC μampsRange/resolution600.0 μA / 0.1 μA
Accuracy1.0% + 2
Hz (V or A input)²Range/resolution99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

Accessories

- 4 mm silicone test lead set

- 80BK Integrated Temperature probe

- Holster

- Installed 9 V battery

- User manual

Assembly Training Kits Sanwa PC20TK

Contact

Assembly Training Kits Sanwa KIT-8D

Contact

Continuity Tester Chauvinx Arnoux C.A 6011

Contact

Digital Multimeter Yokogawa TY520

Contact

Digital Multimeter Yokogawa TY530

Contact

Digital Multimeter Yokogawa TY710

Contact

Digital Multimeter Yokogawa TY720

Contact

LED Stroboscope Fluke 820-2

Contact

Vibration Meter Fluke 805 FC

Contact

Vibration Tester Fluke 810

Contact

Vibration Meter Fluke 805

Contact

Insulation Multimeter Fluke 1577

Contact
Reviews & Comments

0.0/5

(0 ratings)
  • 5 0
  • 4 0
  • 3 0
  • 2 0
  • 1 0

Please login to write review!

Review about this product: