Description
The Model 2100 USB Digital Multimeter is thenewest member of Keithley’s family of high performance DMMs. Its high accuracy (38ppm), 6½-digit resolution is ideal for critical measurements. The Model 2100 features 11 measurement functions and 8 math functions to easily accommodate the most commonly measured parameters. All accessories, such as USB cable, probes, and software, are included with the Model 2100. With its unique combination of high precision and low total cost of ownership, the Model 2100 is an unbeatable value for R&D engineers, test engineers, scientists, and students making basic precision measurements on the bench and in system applications.
High Precision, Low Cost
The Model 2100 provides stability, accuracy, and speed at a very low cost. It has 0.0038% 1-year basic DC voltage accuracy on the 10V range and 0.013% 1-year basic resistance accuracy on the 10kW range. At 6½ digits, the Model 2100 delivers 50 triggered rdgs/s via the USB remote interface. At the fast 4½ digit setting, it reads over 2000 rdgs/s into its 2000 reading internal buffer.
Features:
- High precision 6½-digit DMM for critical measurements at a 5½-digit price
- 11 measurement functions cover most commonly measured parameters
- Fully specified accuracies on all functions for ISO -compliant results
- Included PC software utilities for graphing and data sharing in both Microsoft® Word and Excel
- Rugged construction for durability in bench/portable applications
- Selectable front/rear inputs facilitate bench or rack use
- Includes all accessories, such as startup software, USB cable, power cable, and safety test lead, for lowest total cost
- CE compliant and UL listed
- TMC compliant USB 2.0 interface for use with SCPI test programs
GENERAL SPECIFICATIONS | ||||
Item | Limitation and description | |||
AC CMRR | 70dB | |||
Power supply | 120V/220V/240V | |||
Power line frequency | 50/60Hz auto detected | |||
Power consumption | 25VA max | |||
Operating temperature | 5°C to 40°C | |||
Operating humidity | Maximum relative humidity 80% for temperature up to 31°C, decreasing linearly to 50% relative humidity at 40°C | |||
Storage temperature | -25°C to 65 °C | |||
Operating altitude | Up to 2000 meters above sea level | |||
Bench dimensions (with handles and feet) | 112mm high x 256mm wide x 375 deep (4.4 in x 10.1 in x 14.75 in) | |||
Weight | 4.1 kg / 9 lbs | |||
Safety | IEC61010-1:2001/EN61010-1:2001 (2 nd Edition) Over-Voltage Category CAT II, CAT I 1000V | |||
UL61010-1:2004 Installation CAT II, Measurement CAT III at max. 1000V | ||||
Pollution Degree 2 | ||||
EMC | Conforms to European Union EMC Directive | |||
Warranty | One year | |||
Environment | For indoor use only | |||
Digital I/O interface | USB - compatible Type B connection | |||
DC characteristics: Accuracy 1 ± (% of reading + % of range) | ||||
Function | Range | Resolution | Input resistance | 1 year (23°C ± 5°C) |
DC voltage | 100.0000mV | 0.1uV | > 10GΩ | 0.0055 + 0.0040 |
1.000000V | 1.0uV | > 10GΩ | 0.0045 + 0.0008 | |
10.00000V | 10uV | > 10GΩ | 0.0038 + 0.0006 | |
100.0000V | 100uV | 10MΩ | 0.0050 + 0.0007 | |
1000.000V | 1mV | 10MΩ | 0.0055 + 0.0010 | |
Function | Range | Resolution | Shunt resistance | 1 year (23°C ± 5°C) |
DCI (DC current) | 10.00000mA | 10nA | 5.1Ω | 0.055 + 0.025 |
100.0000mA | 100nA | 5.1Ω | 0.055 + 0.006 | |
11.000000A | 1uA | 0.1Ω | 0.120 + 0.015 | |
3.00000A | 10uA | 0.1Ω | 0.150 + 0.025 | |
Function | Range | Resolution | Test resistance | 1 year (23°C ± 5°C) |
Resistance | 100.0000Ω | 100uΩ | 1mA | 0.015 + 0.005 |
1.000000kΩ | 1mΩ | 1mA | 0.015 + 0.002 | |
10.00000kΩ | 10mΩ | 100uA | 0.013 + 0.002 | |
100.0000kΩ | 100mΩ | 10uA | 0.015 + 0.002 | |
1.000000MΩ | 1Ω | 5uA | 0.017 + 0.002 | |
10.00000MΩ | 10Ω | 500nA | 0.045 + 0.002 | |
100.0000MΩ | 100Ω | 500nA||10MΩ | 1.00 + 0.020 | |
Diode test | 1.0000V | 10uV | 1mA | 0.040 + 0.020 |
Continuity | 1000.00Ω | 10mΩ | 1mA | 0.024 + 0.030 |
Measurement noise rejection DC (60Hz / 50Hz) | ||||
Rate | Digits | CMRR | NMRR | |
10PLC | 6 1/2 | 140dB | 60dB | |
1PLC | 51/2 | 140dB | 60dB | |
Temperature (RTD) | ||||
Range | Resolution | 4-WIRE ACCURACY 1 Year | ||
-100°C to + 100°C | 0.001°C | ±0.1°C | ||
-200°C to + 630°C | 0.001°C | ±0.2°C | ||
RTD TYPE | 100Ω platinum (PT100), D100, F100, PT385, or PT3916 | |||
MAXIMUM LEAD RESISTANCE (each lead) | 12Ω (to achieve rated accuracy) | |||
SENSOR CURRENT | 1mA (pulsed) | |||
AC characteristics | Accuracy ± (% of reading + % of range) | |||
Function | Range | Frequency (Hz) | 1 Year (% of reading) 23º C ± 5º C | |
Frequency and Period | 51/100mV to 750V | 3-5 | 0.10 | |
5-40 | 0.05 | |||
40-300k | 0.01 | |||
Function | Range | Resolution | Frequency (Hz) | 1 year (23°C ± 5°C) |
ACV (AC TRMS voltage) | 100.0000mV | 0.1uV | 3-5 | 1.15 + 0.05 |
5-10 | 0.45 + 0.05 | |||
10-20k | 0.08 + 0.05 | |||
20k-50k | 0.15 + 0.06 | |||
50k-100k | 0.70 + 0.09 | |||
100k-300k | 4.25 + 0.60 | |||
1.000000V to 750.000V | 1.0uV To 1mV | 3-5 | 1.10 + 0.04 | |
5-10 | 0.4 + 0.04 | |||
10-20k | 0.08 + 0.04 | |||
20k-50k | 0.14 + 0.06 | |||
50k-100k | 0.70 + 0.08 | |||
100k-300k | 4.35 + 0.50 | |||
ACi (AC TRMS current) | 1.000000A | 1uA | 3-5 | 1.10 + 0.05 |
5-10 | 0.40 + 0.05 | |||
10-5k | 0.15 + 0.05 | |||
3.000000A | 10uA | 3-5 | 1.25 + 0.07 | |
5-10 | 0.45 + 0.07 | |||
10-5k | 0.20 + 0.07 |
Keithley 2100/120 Product Specifications Summary: (for full specs please see the full specs tab or the data sheet)
Multimeters Template | |
---|---|
Type | Digital |
Style | Bench |
Measures AC V | Yes |
Measures DC V | Yes |
Measures AC A | Yes |
Measures DC A | Yes |
True RMS What's This? | Yes |
Test Equipment General Attributes | |
Power Supply Voltage | 120V 50/60 Hz |
Shipping Weight | 9.50 LBS |
Accessories
- Instruction manual on CD
- Specifications
- LabVIEW® Driver
- Keithley I/O Layer
- USB Cable
- Power Cable
- Safety Test Leads
- KI-Tool
- KI-Link Add-in (Both Microsoft Word and Excel versions)
Please login to write review!