Benchtop Multimeter Keithley 2016
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: sales@lidinco.com
- Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: bn@lidinco.com
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
- Technical Counseling 100% Free
- Free Shipping For 3.000.000vnd Order
Data is being updated
Description
Benchtop Multimeter Keithley 2016
- THD, THD+Noise, and SINAD measurements
- 20Hz 20kHz sine wave generator
- Fast frequency sweeps
- 2016, 2016-P: 9.5Vrms single-ended or 19Vrms differential output
- Individual harmonic magnitude measurements
- 5 standard audio shaping filters
- 13 DMM functions (6-1/2 digits)
Specifications:
GENERAL SPECIFICATIONS | |
POWER SUPPLY | 100V / 120V / 220V / 240V. |
LINE FREQUENCY | 50Hz to 60Hz and 400Hz, automatically sensed at power-up. |
POWER CONSUMPTION | 40 VA. |
OPERATING ENVIRONMENT | Specified for 0°C to 50°C. Specified to 80% R.H. at 35°C. RH at 35°C and at an altitude of up to 2,000 meters. |
STORAGE ENVIRONMENT | –40°C to 70°C. |
WARRANTY | 3 years. |
SAFETY | Conforms to European Union Directive 73/23/EEC EN61010-1. |
EMC | Complies with European Union Directive 89/336/EEC, EN61326-1. |
VIBRATION | MIL-PRF-28800F Class 3 Random. |
WARMUP | 1 hour to rated accuracy. |
DIMENSIONS | Rack Mounting: 89mm high × 213mm wide × 370mm deep (3 1 / 2 in × 8 3 / 8 in × 14 9 / 16 in). |
Bench Configuration (with handle and feet) | 104mm high × 238mm wide × 370mm deep (4 1 / 8 in × 9 3 / 8 in × 14 9 / 16 in). |
NET WEIGHT | 4.2kg (8.8 lbs). |
SHIPPING WEIGHT | 5kg (11 lbs). |
VOLT HERTZ PRODUCT | =8 × 10 7 V·Hz. |
ACCESSORIES SUPPLIED | Model 1751 Safety Test Leads, User Manual, Service Manual. |
DISTORTION CHARACTERISTICS | ||||||||||||||||||
VOLTAGE RANGE | 100mV, 1V, 10V, 100V, 750V (user selectable). | |||||||||||||||||
INPUT IMPEDANCE | 1MΩ paralleled by <100pF | |||||||||||||||||
DISPLAY RANGE | 0–100% or 0–100.00dB | |||||||||||||||||
RESOLUTION | 0.0001% or 0.00001dB | |||||||||||||||||
FUNDAMENTAL FREQUENCY RANGE | 20Hz–20kHz | |||||||||||||||||
HARMONIC FREQUENCY RANGE | 40Hz–50kHz | |||||||||||||||||
FREQUENCY RESOLUTION | 0.008Hz | |||||||||||||||||
FREQUENCY ACCURACY | ±0.01% of reading | |||||||||||||||||
FREQUENCY TEMPERATURE COEFFICIENT | =100ppm over operating temperature range | |||||||||||||||||
| ||||||||||||||||||
External Interface | ||||||||||||||||||
None | C-Message | |||||||||||||||||
CCITT Weighting | CCIR/ARM | |||||||||||||||||
CCIR | “A” Weighting | |||||||||||||||||
NUMBER OF HARMONICS INCLUDED IN THD CALCULATION | 2 to 64 (user selectable) | |||||||||||||||||
HI AND LO CUTOFF FILTERS (bus settable) | 20Hz–50kHz. Can be combined to form brickwall bandpass filter | |||||||||||||||||
Distortion Measurement Reading Rate | ||||||||||||||||||
| ||||||||||||||||||
Frequency Sweep Reading Rate | ||||||||||||||||||
| ||||||||||||||||||
Notes |
|
GENERATOR CHARACTERISTICS | |
FREQUENCY RANGE | 10–20kHz |
FREQUENCY RESOLUTION | 0.007Hz. |
FREQUENCY ACCURACY | ±(0.015% of reading + 0.007Hz) |
FREQUENCY TEMPERATURE COEFFICIENT | <100ppm over operating temperature range. |
SOURCE OUTPUT | |
Waveform | Sinewave |
Amplitude Range | 2V rms (50Ω and 600Ω) or 4V rms (HI Z) |
Amplitude Resolution | 0.5mV rms (50Ω and 600Ω) or 1mV rms (HI Z) |
Amplitude Accuracy | ±(0.3% of setting + 2mV) |
Amplitude Temperature Coefficient | Typically 0.015%/°C |
Amplitude Flatness | ±0.1dB |
Output Impedance | 50O ± 1Ω or 600O ± 10Ω, user selectable |
THD | –64dB |
Noise | 100µV rms |
DC Offset Voltage | ±1.2mV |
INV/PULSE OUTPUT (SINEWAVE MODE) | |
Frequency | Same as source output |
Amplitude Range | 2V rms (50Ω and 600Ω) or 4V rms (HI Z) |
Amplitude Resolution | 0.5mV (50Ω and 600Ω) or 1mV rms (HI Z) |
Amplitude Accuracy | ±(2.0% of setting + 2mV) |
Amplitude Flatness | ±0.1dB |
Output Impedance | Same as Source Output setting |
THD | –64dB |
Noise | 100µV rms |
DC Offset Voltage | ±1.1mV typ., ±13mV max |
INV/PULSE OUTPUT (PULSE MODE) | |
Frequency | Same as source output |
Duty Cycle | 45% ±3% |
Output Impedance | Same output impedance as the source output |
Amplitude | 0.0V ±0.07V to 4.9V ±0.12V pulse open circuit 0.0V ±0.05V to 3.3V ±0.08V pulse 100Ω load |
Overshoot | 1.0V maximum pulse open circuit 0.2V maximum with 100Ω load pulse open circuit |
Undershoot | 1.1V maximum pulse open circuit 0.45V maximum with 100Ω load pulse open circuit |
Notes |
|
DC CHARACTERISTICS | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
CONDITIONS: MED (1 PLC)1 OR SLOW (10 PLC)ACCURACY: ±(PPM OF READING + PPM OF RANGE) OR MED (1 PLC) WITH FILTER OF 10(PPM = PARTS PER MILLION) (E.G., 10PPM = 0.001%) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
DC OPERATING CHARACTERISTICS | |||
FUNCTION | DIGITS | READINGS/s | PLCs |
DCV (all ranges), DCI (all ranges), and 2W Ohms (<10M range) | 6 1 / 2 6 1 / 2 6 1 / 2 5 1 / 2 5 1 / 2 5 1 / 2 4 1 / 2 | 5 30 50 270 500 1000 2000 | 10 1 1 0.1 0.1 0.04 0.01 |
DC SYSTEM SPEEDS | |
RANGE CHANGE | 50 / s |
FUNCTION CHANGE | 45 / s |
AUTORANGE TIME | <30 ms |
ASCII READINGS TO RS-232 (19.2K BAUD) | 55 / s. |
MAX. INTERNAL TRIGGER RATE | 2000 / s. |
MAX. EXTERNAL TRIGGER RATE | 400 / s. |
DC GENERAL | |
LINEARITY OF 10VDC RANGE | ±(2ppm of reading + 1ppm of range) |
DCV, Ω, TEMPERATURE, CONTINUITY, DIODE TEST INPUT PROTECTION | 1000V, all ranges |
MAXIMUM 4WΩ LEAD RESISTANCE | 10% of range per lead for 100Ω and 1kΩ ranges; 1kΩ per lead for all other ranges |
DC CURRENT INPUT PROTECTION | 3A, 250V fuse |
SHUNT RESISTOR | 0.1Ω for 3A, 1A and 100mA ranges. 10Ω for 10mA range |
CONTINUITY THRESHOLD | Adjustable 1O to 1000Ω. |
AUTOZERO OFF ERROR | Add ±(2ppm of range error + 5µV) for <10 minutes and ±1°C change |
OVERRANGE | 120% of range except on 1000V, 3A and Diode. |
DC Notes | |
|
TRUE RMS AC VOLTAGE AND CURRENT CHARACTERISTICS | |||||||
ACCURACY 1 : ±(% of reading + % of range), 23°C ±5 °C | |||||||
VOLTAGE | RANGE | CALIBRATION CYCLE | 3 Hz– 10 Hz | 10 Hz– 20 kHz | 20 kHz– 50 kHz | 50 kHz– 100 kHz | 100 kHz– 300 kHz |
100.0000 mV 1.000000 V 10.00000 V 100.0000 V 750.000 V | 0.1 µV 1.0 µV 10 µV 100 µV 1 mV | 90 Days 1 Year | 0.35+0.03 0.35+0.03 | 0.05+0.03 0.06+0.03 | 0.11+0.05 0.12+0.05 | 0.60+0.08 0.60+0.08 | 4 + 0.5 4 + 0.5 |
TEMPERATURE COEFFICIENT/°C | 0.035+0.003 | 0.005+0.003 | 0.006+0.005 | 0.01+0.006 | 0.03+0.01 | ||
CURRENT RANGE | RESOLUTION | CALIBRATION CYCLE | 3 Hz– 10 Hz | 10 Hz– 3 kHz | 3 kHz- 5 kHz | ||
1.000000 A | 1 µA | 90 Day/1 Year | 0.30+0.04 | 0.10+0.04 | 0.14+0.04 | ||
3.00000 A | 10 µA | 90 Day/1 Year | 0.35+0.06 | 0.15+0.06 | 0.18+0.06 | ||
TEMPERATURE COEFFICIENT/°C | 0.035+0.006 | 0.015+0.006 | 0.015+0.006 |
HIGH CREST FACTOR ADDITIONAL ERROR ±(% of reading) | ||||||||||||||||
CREST FACTOR | 1–2 | 2–3 | 3–4 | 4–5 | ||||||||||||
ADDITIONAL ERROR | 0.05 | 0.15 | 0.30 | 0.40 | ||||||||||||
AC OPERATING CHARACTERISTICS | ||||||||||||||||
FUNCTION | DIGITS | READINGS/s | RATE | BANDWIDTH | ||||||||||||
ACV (all ranges) | 6 1 / 2 | 2s/reading | SLOW | 3 Hz–300 kHz | ||||||||||||
ACI (all ranges) | 6 1 / 2 | 1.4 | MED | 30 Hz–300 kHz | ||||||||||||
6 1 / 2 | 4.8 | MED | 30 Hz–300 kHz | |||||||||||||
6 1 / 2 | 2.2 | FAST | 300 Hz–300 kHz | |||||||||||||
6 1 / 2 | 35 | FAST | 300 Hz–300 kHz | |||||||||||||
ADDITIONAL LOW FREQUENCY ERRORS ±(% of reading) | ||||||||||||||||
FUNCTION | SLOW | MED | FAST | |||||||||||||
20Hz – 30Hz | 0 | 0.3 | - | |||||||||||||
30Hz – 50Hz | 0 | 0 | - | |||||||||||||
50Hz – 100Hz | 0 | 0 | 1.0 | |||||||||||||
100Hz – 200Hz | 0 | 0 | 0.18 | |||||||||||||
200Hz – 300Hz | 0 | 0 | 0.10 | |||||||||||||
> 300Hz | 0 | 0 | 0 | |||||||||||||
AC SYSTEM SPEEDS | ||||||||||||||||
FUNCTION/RANGE CHANGE | 4 / s | |||||||||||||||
AUTORANGE TIME | <3 s | |||||||||||||||
ASCII READINGS TO RS-232 (19.2K BAUD) | 50 / s | |||||||||||||||
MAX. INTERNAL TRIGGER RATE | 300 / s | |||||||||||||||
MAX. EXTERNAL TRIGGER RATE | 260 / s | |||||||||||||||
AC GENERAL | ||||||||||||||||
INPUT IMPEDANCE | 1MΩ ±2% paralleled by <100pF | |||||||||||||||
ACV INPUT PROTECTION | 1000Vp | |||||||||||||||
MAXIMUM DCV | 400V on any ACV range | |||||||||||||||
ACI INPUT PROTECTION | 3A, 250V fuse | |||||||||||||||
BURDEN VOLTAGE | 1A Range: <0.3V rms. 3A Range: <1V rms | |||||||||||||||
SHUNT RESISTOR | 0.1Ω on all ACI ranges | |||||||||||||||
AC CMRR | >70dB with 1kΩ in LΩ lead | |||||||||||||||
MAXIMUM CREST FACTOR | 5 at full scale | |||||||||||||||
VOLT HERTZ PRODUCT | =8 × 10 7 V·Hz | |||||||||||||||
OVERRANGE | 120% of range except on 750V and 3A ranges | |||||||||||||||
AC Notes | ||||||||||||||||
| ||||||||||||||||
TRIGGERING AND MEMORY | ||||||||||||||||
READING HOLD SENSITIVITY | 0.01%, 0.1%, 1%, or 10% of reading | |||||||||||||||
TRIGGER DELAY | 0 to 99 hrs (1ms step size) | |||||||||||||||
EXTERNAL TRIGGER LATENCY | 200µs + <300µs jitter with autozero off, trigger delay = 0 | |||||||||||||||
MEMORY | 1024 readings | |||||||||||||||
MATH FUNCTIONS | ||||||||||||||||
Rel, Min/Max/Average/StdDev (of stored reading), dB, dBm, Limit Test, %, and mX+b with user defined units displayed. | ||||||||||||||||
dBm REFERENCE RESISTANCES | 1 to 9999O in 1Ω increments | |||||||||||||||
STANDARD PROGRAMMING LANGUAGES | ||||||||||||||||
SCPI (Standard Commands for Programmable Instruments) | ||||||||||||||||
REMOTE INTERFACE | ||||||||||||||||
GPIB (IEEE-488.1, IEEE-488.2) and RS-232C | ||||||||||||||||
FREQUENCY AND PERIOD CHARACTERISTICS | ||||||||||||||||
| ||||||||||||||||
Frequency Notes | ||||||||||||||||
| ||||||||||||||||
TEMPERATURE CHARACTERISTICS | ||||||||||||||||
TYPE | RANGE | RESOLUTION | 90 DAY/1 YEAR (23°C ± 5°C) ACCURACY Relative to Reference Junction | |||||||||||||
J | –200 to+760°C | 0.001°C | ±0.5°C | |||||||||||||
K | –200 to + 1372°C | 0.001°C | ±0.5°C | |||||||||||||
T | –200 to + 400°C | 0.001°C | ±0.5°C |
Keithley 2016 Product Specifications Summary: (for full specs please see the full specs tab or the data sheet)
Multimeters Template | |
---|---|
Type | Digital |
Style | Bench |
Measures AC V | Yes |
Measures DC V | Yes |
Measures AC A | Yes |
Measures DC A | Yes |
True RMS What's This? | Yes |
Backlight | No |
Manual/Autoranging What's This? | Auto-ranging |
Analog Bargraph on Display | No |
Test Equipment General Attributes | |
Calibration Included | Factory Calibration |
Power Supply Voltage | 120V 50/60 Hz |
- 4288-1 Rack Mount Kit Single-unit rack mount kit. Height: 88mm (3-1/2 in)
- 4288-2 Rack Mount Kit Dual-unit rack mount kit. Height: 88mm (3-1/2 in)
- 7009-5 RS-232 Cable Shielded
- 8501-1 Trigger Link Cable With Male Micro-DIN Connectors at each End, 1m (3.3 ft)
- 8501-2 Trigger Link Cable With Male Micro-DIN Connectors at each End, 2m (6.6 ft)
- 8502 Micro-DIN to 6 BNCs Adapter Box Discontinued.
- 8503 DIN-to-BNC Trigger Cable 2 Male BNCs, 1m (3.2 ft.)
Accessories
- 4288-1 Rack Mount Kit
Single-unit rack mount kit. Height: 88mm (3-1/2 in)
- 4288-2 Rack Mount Kit
Dual-unit rack mount kit. Height: 88mm (3-1/2 in)
- 7009-5 RS-232 Cable
Shielded
- 8501-1 Trigger Link Cable
With Male Micro-DIN Connectors at each End, 1m (3.3 ft)
- 8501-2 Trigger Link Cable
With Male Micro-DIN Connectors at each End, 2m (6.6 ft)
- 8502 Micro-DIN to 6 BNCs Adapter Box
Discontinued.
- 8503 DIN-to-BNC Trigger Cable
2 Male BNCs, 1m (3.2 ft.)
Please login to write review!