  • Current Range:
  • Voltage Range:
  • Display Resolution:
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Data is being updated

Description

The 7½-digit 2010 Series Low Noise Multimeter combines cost effectiveness and high resolution with the throughput and accuracy needed for high speed DMM applications such as testing precision sensors, transducers, A/D and D/A converters, regulators, references, connectors, switches, and relays. Based on the same high speed, low noise A/D converter technology as the 2000, 2001, and 2002 Series, the 2010 Series adds four unique resistance measurement functions that make it ideal for characterizing the resistance, linearity, or isolation of contacts, connectors, switches, or relays.  

2010

Features:

  • 7-1/2 digit resolution 
  • 100nV rms noise floor 
  • 7ppm DCV repeatability 
  • Built-in 10-channel scanner mainframe 
  • Dry circuit and low power measurement mode 
  • 15 measurement functions including support for RTD and thermocouple temperature measurements 
  • Built-in ratio measurement function 
  • GPIB and RS-232 interfaces 

  

General specifications
POWER SUPPLY100V / 120V / 220V / 240V
LINE FREQUENCY50Hz to 60Hz and 440Hz, automatically sensed at power-up
POWER CONSUMPTION22VA
VOLT HERTZ PRODUCT=8 × 10 7 V·Hz
OPERATING ENVIRONMENTSpecified for 0° to 50°C. Specified to 80% R.H. at 35°C
STORAGE ENVIRONMENT–40° to 70°C
ALTITUDEUp to 2000 meters
SAFETYConforms to European Union Directive 73/23/EEC EN 61010-1, Cat II
EMCComplies with European Union Directive 89/336/EEC, EN 61326-1
VIBRATIONMIL-PRF-28800F Class 3 Random
WARMUP2 hours to rated accuracy
DIMENSIONSRack Mounting89mm high × 213mm wide × 370mm deep (3½ in × 8 3 / 8 in × 14 9 / 16 in)
Bench Configuration (with handle and feet)104mm high × 238mm wide × 370mm deep (4 1 / 8 in × 9 3 / 8 in × 14 9 / 16 in)
SHIPPING WEIGHT5kg (11 lbs)

 

DC VOLTAGE
RangeResolutionAccuracy 23°C ± 5°C ±(ppm of rdg. + ppm of range)Input Resistance
90 Day1 Year
100.00000 mV10 nV25 + 937 + 9> 10 GΩ
1.0000000 V100 nV18 + 225 + 2> 10 GΩ
10.000000 V1 µV18 + 424 + 4> 10 GΩ
100.00000 V10 µV25 + 535 + 510 MΩ ±1%
1000.0000 V100 µV31 + 641 + 610 MΩ ±1%

 

RESISTANCE
RangeResolutionAccuracy 23°C ± 5°C ±(ppm of rdg. + ppm of range)Test Current
90 Day1 Year
10.000000 Ω1 µΩ40 + 960 + 910 mA
100.00000 Ω10 µΩ36 + 952 + 91 mA
1.0000000 kΩ100 µΩ33 + 250 + 21 mA
10.000000 kΩ1 mΩ32 + 250 + 2100 µA
100.00000 kΩ10 mΩ40 + 470 + 410 µA
1.0000000 MΩ100 mΩ50 + 470 + 410 µA
10.000000 MΩ1 Ω200 + 4400 + 4640 nA//10 MΩ
100.00000 MΩ10 Ω1500 + 41500 + 4640 nA//10 MΩ

 

DC CURRENT
RangeResolutionAccuracy 23°C ± 5°C ±(ppm of rdg. + ppm of range)Burden Voltage
90 Day1 Year
10.000000 mA1 nA300 + 80500 + 80< 0.15 V
100.00000 mA10 nA300 + 800500 + 800< 0.18 V
1.0000000 A100 nA500 + 80800 + 80< 0.35 V
3.000000 A1 µA1200 + 401200 + 40< 1 V

 

CONTINUITY 2W
RangeResolutionAccuracy 23°C ± 5°C ±(ppm of rdg. + ppm of range)Test Current
90 Day1 Year
1 kΩ100 mΩ100 + 100120 + 1001 mA

 

DIODE TEST
RangeResolutionAccuracy 23°C ± 5°C ±(ppm of rdg. + ppm of range)Test Current
90 Day1 Year
10.000000 V1 µV30 + 740 + 71 mA
4.400000 V1 µV30 + 740 + 7100 µA
10.000000 V1 µV30 + 740 + 710 µA

 

DC OPERATING CHARACTERISTICS
FunctionDigitsReadings/sPLCs
10.000000 V4 (3)5
30 (27)1
50 (44)1
260 (220)0.1
490 (440)0.1
1000 (1000)0.04
2000 (1800)0.01

 

DC NOISE PERFORMANCE
RateDigitsRMS Noise 100mV Range (2 min.)RMS Noise 10V Range (2 min.)NMRRCMRR
5 PLC110 nV1.2 µV60 dB140 dB
1 PLC125 nV1.4 µV60 dB140 dB
0.1 PLC1.9 µV11.5 µV 80 dB
0.01 PLC2.9 µV139 µV 80 dB

 

TRUE RMS AC VOLTAGE AND CURRENT CHARACTERISTICS
Voltage RangeResolutionFrequency RangeAccuracy (1 Year) ±(% of reading + % of range)
100 mV to 750 V0.1 µV to 1 mV3 Hz–10 Hz0.35 + 0.03
10 Hz–20 kHz0.06 + 0.03
20 kHz–50 kHz0.12 + 0.05
50 kHz–100 kHz0.60 + 0.08
100 kHz–300 kHz4 + 0.5

 

AC OPERATING CHARACTERISTICS
FunctionDigitsReadings/sRateBandwidth
ACV (all ranges), and ACI (all ranges)0.5 (0.4)SLOW3 Hz–300 kHz
1.4 (1.5)MED30 Hz–300 kHz
4.0 (4.3)MED30 Hz–300 kHz
2.2 (2.3)FAST300 Hz–300 kHz
35 (30)FAST300 Hz–300 kHz

 

FREQUENCY AND PERIOD CHARACTERISTICS
ACV RangeFrequency RangePeriod RangeGate TimeResolution ±(ppm of reading)Accuracy 90 Day/1 Year ±(% of reading)
100 mV to 750 V3 Hz to 500 kHz333 ms to 2 µs1 s0.30.01

 

TEMPERATURE CHARACTERISTICS
Thermocouple
TypeRangeResolutionAccuracy 90 Day/1 Year (23°C ± 5°C) Relative to Reference JunctionUSING 2001-TCSCAN
J–200 to + 760°C0.001°C±0.5°C±0.65°C
K–200 to + 1372°C0.001°C±0.5°C±0.70°C
N–200 to + 1300°C0.001°C±0.5°C±0.70°C
T–200 to + 400°C0.001°C±0.5°C±0.68°C
4-WIRE RTD
RangeResolutionAccuracy 90 Day/1 Year (23°C ± 5°C)Accuracy 2 Years (23°C ± 5°C)
–100° to +100°C0.001°C±0.08°C±0.12°C
–200° to +630°C0.001°C±0.14°C±0.18°C

Keithley 2010 Product Specifications Summary: (for full specs please see the full specs tab or the data sheet)

Multimeters Template

TypeDigital
StyleBench
Measures AC VYes
Measures DC VYes
Measures AC AYes
Measures DC AYes
True RMS What's This?Yes
BacklightNo
Manual/Autoranging What's This?Auto-ranging
Analog Bargraph on DisplayNo

Test Equipment General Attributes

Calibration IncludedFactory Calibration
Power Supply Voltage120V 50/60 Hz

Accessories

- Model 1751 Safety Test Leads 

- User Manual 

- Service Manual 

Reviews & Comments

0.0/5

(0 ratings)
  • 5 0
  • 4 0
  • 3 0
  • 2 0
  • 1 0

Please login to write review!