Benchtop Multimeter Keithley 2000, 6-1/2-Digit, GPIB/RS232

Benchtop Multimeter Keithley 2000, 6-1/2-Digit, GPIB/RS232

SKU:
2000-GPIB/RS232
Brand:
Warranty:
N/A
Price: Contact
  • Current Range:
  • Voltage Range:
  • Display Resolution:
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Data is being updated

Description

The 6½-digit 2000 Series offers a unique combination of high-precision, cost-effectiveness, and flexibility. Based on the same high-speed, low-noise A/D converter technology found in our 7½- and 8½-digit multimeters, this DMM offers market-leading speed and accuracy.  For greater flexibility, a built-in card slot on the rear panel allows an additional multiplexer card for multi-point measurement applications.

Features


- 13 built-in measurement functions 
- 2000 readings/second at 4-1/2 digits 
- Optional scanner cards for multipoint measurements 
- GPIB and RS-232 interfaces 
- Fluke 8840/42 command set

Keithley 2000 lidinco 

General Specification 
POWER SUPPLY 100V / 120V / 220V / 240V 
LINE FREQUENCY 50Hz to 60Hz and 400Hz, automatically sensed at power-up 
POWER CONSUMPTION 22 VA 
OPERATING ENVIRONMENT Specified for 0°C to 50°C. Specified to 80% R.H. at 35°C. Altitude up to 2000 meters. 
STORAGE ENVIRONMENT –40°C to 70°C 
WARRANTY 1 year 
EMC Conforms to European Union EMC Directive 
SAFETY Conforms to European Union Low Voltage Directive 
VIBRATION MIL-PRF-28800F Class 3 Random 
WARMUP 1 hour to rated accuracy 
DIMENSIONS Rack Mounting 89mm high x 213mm wide x 370mm deep (3.5 in. x 8.38 in. x 14.56 in.) 
Bench Configuration (with handle and feet) 104mm high x 238mm wide x 370mm deep (4.13 in. x 9.38 in. x 14.56 in.) 
NET WEIGHT 2.9kg (6.3 lbs) 
SHIPPING WEIGHT 5kg (11 lbs) 
VOLT HERTZ PRODUCT =8 x 10 7 V·Hz 

  

DC CHARACTERISTICS 
CONDITIONS MED (1 PLC) 1 or SLOW (10 PLC) or MED (1 PLC) with filter of 10 
ACCURACY ±(ppm of reading + ppm of range) (ppm = parts per million) (e.g., 10ppm = 0.001%) 
FUNCTION RANGE RESOLUTION TEST CURRENT OR BURDEN VOLTAGE (±5%) INPUT RESISTANCE 24 HOUR 23°C ± 1° 90 DAY 23°C ± 5° 1 YEAR 23°C ± 5° TEMPE- RATURE COEFF- ICIENT 0°–18°C & 28°–50°C 
Voltage 100.0000mV 0.1 µV   >10GΩ 30+30 40+35 50+35 2+6 
1.000000V 1.0µV   >10GΩ 15+6 25+7 30+7 2+1 
10.00000V 10µV   >10GΩ 15+4 20+5 30+5 2+1 
100.0000V 100µV   10MΩ±1% 15+6 30+6 45+6 5+1 
1000.000V 1mV   10MΩ±1% 20+6 35+6 45+6 5+1 
Resistance 100.0000Ω 100µΩ 1mA   30+30 80+40 100+40 8+6 
1.000000kΩ 1mΩ 1mA   20+6 80+10 100+10 8+1 
10.00000kΩ 10mΩ 100µA   20+6 80+10 100+10 8+1 
100.0000kΩ 100mΩ 10µA   20+6 80+10 100+10 8+1 
1.000000MΩ  10µA   20+6 80+10 100+10 8+1 
10.00000MΩ 10Ω 700nA// 10MΩ   150+6 200+10 400+10 95+1 
100.0000MΩ 100Ω 700nA// 10MΩ   800+30 1500+30 1500+30 900+1 
Current 10.00000mA 10nA <0.15V   60+30 300+80 500+80 50+5 
100.0000mA 100nA <0.03V   100+300 300+800 500+800 50+50 
1.000000A 1µA <0.3V   200+30 500+80 800+80 50+5 
3.00000A 10µA <1V   1000+15 1200+40 1200+40 50+5 
Current 1 kΩ 100 mΩ 1 mA   40+100 100+100 120+100 8+1 
Diode Test 3.00000V 10 µV 1 mA   20+6 30+7 40+7 8+1 
10.00000V 10 µV 100µA   20+6 30+7 40+7 8+1 
10.00000V 10 µV 10µA   20+6 30+7 40+7 8+1 
DC OPERATING CHARACTERISTICS 
FUNCTION DIGITS READINGS/s PLCs 
DCV (all ranges), DCI (all ranges), and Ohms (<10M range) 6.5 5 10 
6.5 30 1 
6.5 50 1 
5.5 270 0.1 
5.5 500 0.1 
5.5 1000 0.04 
4.5 2000 0.01 
DC SYSTEM SPEEDS 
RANGE CHANGE 50/s 
FUNCTION CHANGE 45/s 
AUTORANGE TIME <30 ms 
ASCII READINGS TO RS-232 (19.2K BAUD) 55/s 
MAX. INTERNAL TRIGGER RATE 2000/s. 
MAX. EXTERNAL TRIGGER RATE 500/s 
DC GENERAL 
LINEARITY OF 10VDC RANGE ±(1ppm of reading + 2ppm of range) 
DCV, Ω, TEMPERATURE, CONTINUITY, DIODE TEST INPUT PROTECTION 1000V, all ranges 
MAXIMUM 4WΩ LEAD RESISTANCE 10% of range per lead for 100Ω and 1kΩ ranges; 1kΩ per lead for all other ranges 
DC CURRENT INPUT PROTECTION 3A, 250V fuse 
SHUNT RESISTOR 0.1Ω for 3A, 1A and 100mA ranges. 10Ω for 10mA range 
CONTINUITY THRESHOLD Adjustable 1Ω to 1000Ω 
AUTOZERO OFF ERROR Add ±(2ppm of range error + 5µV) for <10 minutes and ±1°C change 
OVERRANGE 120% of range except on 1000V, 3A and Diode 
SPEED AND NOISE REJECTION 
RATE READINGS/S DIGITS RMS NOISE 10V RANGE NMRR CMRR 
10 PLC 5 6.5 < 1.5 µV 60 dB 140 dB 
1 PLC 50 6.5 < 4 µV 60 dB 140 dB 
0.1 PLC 500 5.5 < 22 µV   80 dB 
0.01 PLC 2000 4.5 < 150 µV   80 dB 
DC Notes 
  1. Add the following to “ppm of range” uncertainty:1V and 100V, 2ppm; 100mV, 15ppm; 100Ω, 15ppm; 1K-1MΩ, 2ppm; 10mA and 1A, 10ppm; 100mA, 40ppm 
  2. Speeds are for 60Hz operation using factory default operating conditions (*RST). Autorange off, Display off, Trigger delay = 0 
  3. Speeds include measurement and binary data transfer out the GPIB 
  4. Auto zero off 
  5. Sample count = 1024, auto zero off 
  6. Auto zero off, NPLC = 0.01 
  7. Ohms = 24 readings/second 
  8. 1 PLC = 16.67ms @ 60Hz, 20ms @ 50Hz/400Hz. The frequency is automatically determined at power up 
  9. For signal levels >500V, add 0.02ppm/V uncertainty for the portion exceeding 500V 
  10. Add 120ms for ohms 
  11. Must have 10% matching of lead resistance in Input HI and LO 
  12. For line frequency ±0.1% 
  13. For 1kΩ unbalance in LO lead 
  14. Relative to calibration accuracy 
  15. Specifications are for 4-wire ohms. For 2-wire ohms, add 1Ω additional uncertainty 
  16. For rear inputs, add the following to Temperature Coefficient “ppm of reading” uncertainty: 10MΩ 70ppm, 100MΩ 385ppm. Operating environment specified for 0° to 50°C and 50% RH at 35°C 

  

TRUE RMS AC VOLTAGE AND CURRENT CHARACTERISTICS 
ACCURACY ±(% of reading + % of range), 23°C ±5 °C 
VOLTAGE RANGE RESOLUTION CALIBRATION CYCLE 3 Hz– 10 Hz 10 Hz– 20 kHz 20 kHz– 50 kHz 50 kHz– 100 kHz 100 kHz– 300 kHz 
100.0000mV 0.1 µV   
1.000000V 1.0 µV 90 Days 0.35+0.03 0.05+0.03 0.11+0.05 0.60+0.08 4+0.5 
10.00000V 10 µV   
100.0000V 100 µV 1 Year 0.35+0.03 0.06+0.03 0.12+0.05 0.60+0.08 4+0.5 
750.000V 1 mV   
    TEMPERATURE COEFFICIENT/°C 0.035+ 0.003 0.005+ 0.003 0.006+ 0.005 0.01+ 0.006 0.03+ 0.01 
CURRENT RANGE RESOLUTION CALIBRATION CYCLE 3 Hz– 10 Hz 10 Hz– 3 kHz 3 kHz- 5 kHz     
1.000000A 1 µA 90 Day/ 1 Year 0.30+ 0.04 0.10+ 0.04 0.14+ 0.04     
3.00000A 10 µA 90 Day/ 1 Year 0.35+ 0.06 0.15+ 0.06 0.18+ 0.06     
    TEMPERATURE COEFFICIENT/°C 0.035+ 0.003 0.015+ 0.006 0.015+ 0.006     
HIGH CREST FACTOR ADDITIONAL ERROR ±(% of reading) 
CREST FACTOR 1–2 2–3 3–4 4–5 
ADDITIONAL ERROR 0.05 0.15 0.30 0.40 
AC OPERATING CHARACTERISTICS 
FUNCTION DIGITS READINGS/s RATE BANDWIDTH 
ACV (all ranges), and ACI (all ranges) 6.5 2s/reading SLOW 3 Hz–300 kHz 
6.5 1.4 MED 30 Hz–300 kHz 
6.5 4.8 MED 30 Hz–300 kHz 
6.5 2.2 FAST 300 Hz–300 kHz 
6.5 35 FAST 300 Hz–300 kHz 
ADDITIONAL LOW FREQUENCY ERRORS ±(% of reading) 
  SLOW MED FAST 
20Hz – 30Hz 0 0.3   
30Hz – 50Hz 0 0   
50Hz – 100Hz 0 0 1.0 
100Hz – 200Hz 0 0 0.18 
200Hz – 300Hz 0 0 0.10 
> 300Hz 0 0 0 
AC SYSTEM SPEEDS 
FUNCTION/RANGE CHANGE 4/s 
AUTORANGE TIME <3s 
ASCII READINGS TO RS-232 (19.2k BAUD) 50/s 
MAX. INTERNAL TRIGGER RATE 300/s 
MAX. EXTERNAL TRIGGER RATE 300/s 
AC GENERAL 
INPUT IMPEDANCE 1MΩ ±2% paralleled by <100pF 
ACV INPUT PROTECTION 1000Vp 
MAXIMUM DCV 400V on any ACV range 
ACI INPUT PROTECTION 3A, 250V fuse 
BURDEN VOLTAGE 1A Range: <0.3V rms. 3A Range: <1V rms 
SHUNT RESISTOR 0.1Ω on all ACI ranges 
AC CMRR >70dB with 1kΩ in LO lead 
MAXIMUM CREST FACTOR 5 at full scale 
VOLT HERTZ PRODUCT =8 x 10 7 V·Hz 
OVERRANGE 120% of range except on 750V and 3A ranges 
AC Notes 
  1. Specifications are for SLOW rate and sinewave inputs >5% of range 
  2. Speeds are for 60 Hz operation using factory default operating conditions (*RST). Auto zero off, Auto range off, Display off, includes measurement and binary data transfer out the GPIB 
  3. 0.01% of step settling error. Trigger delay = 400ms 
  4. Trigger delay = 0 
  5. DETector:BANDwidth 300, NPLC = 0.01 
  6. Maximum useful limit with trigger delay = 175ms 
  7. Applies to non-sinewaves >5Hz and <500Hz. (Guaranteed by design for Crest Factors >4.3) 
  8. Applies to 0°–18°C and 28°–50°C 
  9. For signal levels > 2.2A, add additional 0.4% to “of reading” uncertainty 
  10. Typical uncertainties. Typical represents two sigma or 95% of manufactured units measure < 0.35% of reading and three sigma or 99.7% < 1.06% of reading 

Keithley 2000 Product Specifications Summary: (for full specs please see the full specs tab or the data sheet) 

Multimeters Template 

Type Digital 
Style Bench 
Measures AC V Yes 
Measures DC V Yes 
Measures AC A Yes 
Measures DC A Yes 
True RMS What's This? Yes 

Test Equipment General Attributes 

Power Supply Voltage 120V 50/60 Hz 

Accessories

Reviews & Comments

0.0/5

(0 ratings)
  • 5 0
  • 4 0
  • 3 0
  • 2 0
  • 1 0

Please login to write review!

Review about this product: