High-Precision Handheld DIGITAL MULTIMETER DT4281

High-Precision Handheld DIGITAL MULTIMETER DT4281

SKU:
DT4281
Brand:
Warranty:
N/A
Price: Contact
  • Current Range:
  • Voltage Range:
  • Accuracy:
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Data is being updated

Description

The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters. The DT4281 is our top-of-the-line high-precision 60000 count digital multimeter with all of the functions and features required for advanced testing in complex power and electrical applications. 

CAT IV 600 V, CAT III 1000 V 

Đồng hồ vạn năng độ chính xác cao DT4281 - Hioki Nhật Bản 

Features: 

- 60000 count, 5-digit display, high-resolution measurements
- ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Measures large currents with optional clamp probe (only for DT4281, which has no 10 A terminal for accident prevention)
- Terminal shutter mechanism (prevents erroneous test lead insertion)
- Dual display lets you check voltage and frequency simultaneously

Specifications:

DC voltage60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt.
AC voltage 45 to 65 Hz60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy: ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3)
DC + AC voltage 45 to 65 Hz6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy: ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3)
Resistance60.000 Ω to 600.0 MΩ, 8 ranges, Basic accuracy: ±0.03 % rdg. ±2 dgt.
DC current600.00 μA to 600.00 mA, 4 ranges Basic accuracy: ±0.05 % rdg. ±5 dgt.
AC current 45 to 65 Hz600.00 μA to 600.00 mA, 4 ranges Basic accuracy: ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3) Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range)
AC Current (use with Clamp on probes) 40 to 1 kHz10.00 A to 1000 A, 7 ranges Add the Clamp on probe accuracy to Basic accuracy: ±0.6 % rdg. ±2 dgt. (True RMS, crest factor 3)
PeakDC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated) AC V, DC/AC A measurement: Signal width 1 msec or more (single), 250 μsec or more (repeated)
C (capacitance)1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt.
Continuity CheckContinuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more
Diode testOpen terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages
FrequencyAC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio) 99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt.
dB conversionStandard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages Display dB conversion value of AC voltage (dBV)
TemperatureK: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) (use with optional probe DT4910) Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C
Other functionsFilter function (Remove harmonic noise, use only at 600 VAC, 1000 VAC ranges), Display value hold, Auto hold, Max/Min value display, Sampling select, Relative display, Measurement memory (400 data), Auto-power save, USB communication (option), 4-20 mA % conversion
DisplayMain and sub displays: 5-digits LCD, max. 60000 digits
Display refresh rates5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s )
Power supplyLR6 (AA) alkaline batteries × 4, Continuous use: 100 hours
Dimensions and mass93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries)
AccessoriesTest Lead L9207-10 × 1, Instruction Manual × 1, LR6 Alkaline Battery × 4
  • Test Lead L9207-10 × 1
  • Instruction Manual × 1
  • LR6 Alkaline Battery × 4

Accessories

- Test Lead L9207-10 × 1

- Instruction Manual × 1

- LR6 Alkaline Battery × 4

Assembly Training Kits Sanwa PC20TK

Contact

Assembly Training Kits Sanwa KIT-8D

Contact

Continuity Tester Chauvinx Arnoux C.A 6011

Contact

Digital Multimeter Yokogawa TY520

Contact

Digital Multimeter Yokogawa TY530

Contact

Digital Multimeter Yokogawa TY710

Contact

Digital Multimeter Yokogawa TY720

Contact

DC HIGH VOLTAGE PROBE Hioki P2000

Contact

Insulation Tester Hioki 3174

Contact

Insulation Tester Hioki 3159

Contact

Insulation Tester Hioki 3153

Contact

Hioki Insulation Tester ST5520

Contact

Hioki Super Mω Hitester SM7810

Contact

Hioki Super Megohm Meter SM7120

Contact

Super Megohm Meter Hioki Sm7420

Contact
Reviews & Comments

0.0/5

(0 ratings)
  • 5 0
  • 4 0
  • 3 0
  • 2 0
  • 1 0

Please login to write review!

Review about this product: