CLAMP ON AC/DC HiTESTER 3290, 3290-10
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: sales@lidinco.com
- Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: bn@lidinco.com
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
- Technical Counseling 100% Free
- Free Shipping For 3.000.000vnd Order
Data is being updated
Description
Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The 3290 and 3290-10 feature detachable clamp sensors to offer a maximum 2000 A current range.
CAT III 600 V
For Clamp Sensor
Feature
• Choose from three sensors
• Measure up to 100 A, 200 A, or 2000 A rated current
• Correctly measure for inverter current with AC+DC mode and True RMS rectification
• Choice of output (Simultaneous output): Effective value, waveform, frequency, and integral value output
• Choice of response time with three steps
• Model 3290-10 supports current integration and operating ratio measurements
Specifications
3290 | 3290-10 | |
Measurement modes | DC, AC+DC (True RMS), AC (True RMS/ Average rectified) | DC, AC+DC (True RMS), AC (True RMS) |
Peak value display | Absolute value (of waveform peak) | Polarities independently (±peak value of waveform, in DC mode) |
Separate AC/DC output | Separate constituent element of AC, DC | N/A |
Output (terminal 1) | Current waveform or true RMS value (2 V / setting range), Frequency value (1 VDC / setting range) | Current waveform or true RMS value (2 V / setting range) |
Output (terminal 2) | Rms current/Low-battery warning switch | Current integral value (1 VDC / setting range) |
Integral current measurement | N/A | ±, +, - integral, average value |
Rate measurement | N/A | Operating time rate, total measurement time |
Timer settings | N/A | 99 h, 59 min. (for repeated up to 20 times) |
Data storage | N/A | Peak, integral value, operating time rate, or other |
Basic accuracy at DC current | 20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A 20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A 200.0/ 2000A (using the CT9693 sensor): ±1.8 % rdg. ±1.0 A/ ±5 A | |
Basic accuracy at AC current (45 to 66 Hz) | 20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A 20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A 200.0/ 2000A (using the CT9693 sensor): ±1.3 % rdg. ±0.8 A/ ±3 A | |
Voltage measurement | N/A | |
Frequency measurement | 1.00Hz to 1000Hz, Basic accuracy: ±0.3% rdg. ±1dgt. | |
Crest factor | 2.5 or less, or rated peak value of sensor | |
Frequency characteristics | DC, or 1 Hz to 1 kHz (accuracy guaranteed range) At monitor output: based on the using sensor | |
Other functions | Switching measurement response speed, Turning the filter on/off (fc=550 Hz) | |
Power supply | LR6 (AA) alkaline batteries ×4, Continuous use : 22 hr, or AC adapter 9445-02/ -03 (The 3290-10 only: +8.4 to 15.6 V DC external power supply possible) | |
Dimensions and mass | 155 mm (6.10 in) W × 98 mm (3.86 in) H × 47 mm (1.85 in) D, 545 g (19.2 oz) |
Accessories
- Strap ×1
- LR6 (AA) alkaline batteries × 4
- Instruction manual ×1